10. Handling of modules
10-1 Inserting the FPC into its connector and pulling it out.
10-2 About handling of FPC
10-3 Mounting of the module
10-4 Cautions in assembly / Handling pre cautions.
① Be sure to turn off the power supply and the signals when inserting or disconnecting the cable.
② Please insert for too much stress not to join FPC in the case of insertion of FPC.
① The bending radius of the FPC should be more than 1.4mm, and it should be bent evenly.
② Do not dangle the LCD module by holding the FPC, or do not give any stress to it.
① The module should be held on to the plain surface. Do not give any warping or twisting stress to
② Please consider that GND can ground a modular metal portion etc. so that static electricity is not
As the polarizer can be easily scratched, be most careful in handling it.
① Work environments in assembly.
② How the remove dust on the polarizer
③ In the case of the module’s metal part (shield case) is stained, wipe it with a piece of dry, soft
④ If a water dropped, etc. remains stuck on the polarizer for a long time, it is apt to get discolored or
⑤ As a glass substrate is used for the TFT-LCD panel, if it is dropped on the floor or hit by
⑥ Since CMOS LSI is used in this module, take care of static electricity and take the human earth into
a) Implement more than 1MΩ conductive treatment ( by placing a conductive mat or applying
b) No dusts come in to the working room. Place an adhesive, anti-dust mat at the entrance of the room.
c) Humidity of 50~70% and temperature of 15~27℃ are desirable.
d) All workers wear conductive shoes, conductive clothes, conductive fingerstalls and grounding
e) Use a blower for electrostatic removal. Set it in a direction slightly tilt downward so that each
a) Blow out dust by the use of an N2 blower with antistatic measures taken. Use of an ionized air
b) When the panel surface is soiled, wipe it with soft cloth.
the module.
charged to a module.
Working under the following environments is desirable:
cloth. If rather difficult, give a breath on the metal part to clean better.
cause stains. Wipe it immediately.
something hard, it may be broken or chipped off.
consideration when handling.
Conductive paint ) on the floor or tiles.
belts without fail.
Module can be well subjected to its wind. Set the blower at an optimum distance between the
blower and the module.
Gun is recommendable.
LCM- 05042 Page 18 of 23