NL128102AC31-02 NEC Electronics, NL128102AC31-02 Datasheet - Page 49

no-image

NL128102AC31-02

Manufacturer Part Number
NL128102AC31-02
Description
Manufacturer
NEC Electronics
Datasheet

Specifications of NL128102AC31-02

Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
NL128102AC31-02
Manufacturer:
NEC
Quantity:
1 000
Part Number:
NL128102AC31-02A
Manufacturer:
NEC
Quantity:
1 000
(4) INITIAL VALUE CHANGE FUNCTIONS
This module changes initial value, OSD items, and so on in customers.
The changed initial value becomes initial value in each preset timing, and is applicable when it is reset
(including All Reset).
1.ADC CALIB
2.BRIGHTNESS
3.COLOR
4.CONTRAST
5.LCD DATA
How to transpose to initial value change mode.
Operation
How to return to normal mode
Connect UP to GND while SEL is connected to GND when OSD function is "information".
SEL, UP, DOWN and EXIT
Connect EXIT to GND or turn off "Power" when OSD closes.
Item
xAUTO GAIN
yAUTO GAIN RESET
The maximum value of brightness can change.
Initial value: 100
The initial value of white color level and RGB each color level can change.
Initial value: 128
The initial value of white contrast and RGB each contrast can change.
Initial value: 128
xMODE
yH.POSITION
zV.POSITION
{SIZE
The initial value of the left/right position of the display position can
change.
According to the amplitude of the input signal, the gain can be automatically
adjusted. (at analog signal input : valid, at digital signal input: invalid)
The values in x are returned to the statuses when shipping from the factry.
Preset timing No. is displayed. But it isn't identical with the number of the
The initial value of the up/down position of the display position can
change.
The initial value of the double value can change.
table of 3.7 PRESET TIMINGS. (There is no adjustment function.)
Data Sheet EN0545EJ1V0DS
Function
NL128102AC31-02A
49

Related parts for NL128102AC31-02