EPM9560ARI208-10 Altera, EPM9560ARI208-10 Datasheet - Page 15

IC MAX 9000 CPLD 560 208-RQFP

EPM9560ARI208-10

Manufacturer Part Number
EPM9560ARI208-10
Description
IC MAX 9000 CPLD 560 208-RQFP
Manufacturer
Altera
Series
MAX® 9000r
Datasheet

Specifications of EPM9560ARI208-10

Programmable Type
In System Programmable
Delay Time Tpd(1) Max
10.0ns
Voltage Supply - Internal
4.5 V ~ 5.5 V
Number Of Logic Elements/blocks
35
Number Of Macrocells
560
Number Of Gates
12000
Number Of I /o
153
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
208-RQFP
Voltage
3.3V/5V
Memory Type
EEPROM
Number Of Logic Elements/cells
35
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Features
-
Other names
544-2364

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EPM9560ARI208-10
Manufacturer:
CML
Quantity:
2 000
Part Number:
EPM9560ARI208-10
Manufacturer:
ALTERA
Quantity:
5 530
Part Number:
EPM9560ARI208-10
Manufacturer:
ALTERA
Quantity:
1
Part Number:
EPM9560ARI208-10
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EPM9560ARI208-10
Manufacturer:
ALTERA
0
Part Number:
EPM9560ARI208-10N
Manufacturer:
ALTERA
Quantity:
5 530
Part Number:
EPM9560ARI208-10N
Manufacturer:
ALTERA
Quantity:
1 000
Part Number:
EPM9560ARI208-10N
Manufacturer:
ALTERA
Quantity:
3 562
Part Number:
EPM9560ARI208-10N
Manufacturer:
ALTERA
0
Altera Corporation
A row interconnect channel can be fed by the output of the macrocell
through a 4-to-1 multiplexer that the macrocell shares with three column
channels. If the multiplexer is used for a macrocell-to-row connection, the
three column signals can access another row channel via an additional
3-to-1 multiplexer. Within any LAB, the multiplexers provide all
48 column channels with access to 32 row channels.
Row-to-I/O Cell Connections
Figure 8
and IOCs. An input signal from an IOC can drive two separate row
channels. When an IOC is used as an output, the signal is driven by a
10-to-1 multiplexer that selects the row channels. Each end of the row
channel feeds up to eight IOCs on the periphery of the device.
Figure 8. MAX 9000 Row-to-IOC Connections
Column-to-I/O Cell Connections
Each end of a column channel has up to 10 IOCs (see
signal from an IOC can drive two separate column channels. When an IOC
is used as an output, the signal is driven by a 17-to-1 multiplexer that
selects the column channels.
Row FastTrack
Interconnect
illustrates the connections between row interconnect channels
96
MAX 9000 Programmable Logic Device Family Data Sheet
96
96
Each IOC can drive up to
two row channels.
10
10
Each IOC is driven by
a 10-to-1 multiplexer.
IOC1
IOC8
Figure
9). An input
15

Related parts for EPM9560ARI208-10