EP1C20F324I7 Altera, EP1C20F324I7 Datasheet - Page 21

IC CYCLONE FPGA 20K LE 324-FBGA

EP1C20F324I7

Manufacturer Part Number
EP1C20F324I7
Description
IC CYCLONE FPGA 20K LE 324-FBGA
Manufacturer
Altera
Series
Cyclone®r
Datasheet

Specifications of EP1C20F324I7

Number Of Logic Elements/cells
20060
Number Of Labs/clbs
2006
Total Ram Bits
294912
Number Of I /o
233
Voltage - Supply
1.425 V ~ 1.575 V
Mounting Type
Surface Mount
Operating Temperature
-40°C ~ 100°C
Package / Case
324-FBGA
Family Name
Cyclone®
Number Of Logic Blocks/elements
20060
# I/os (max)
233
Frequency (max)
320.1MHz
Process Technology
0.13um (CMOS)
Operating Supply Voltage (typ)
1.5V
Logic Cells
20060
Ram Bits
294912
Operating Supply Voltage (min)
1.425V
Operating Supply Voltage (max)
1.575V
Operating Temp Range
-40C to 100C
Operating Temperature Classification
Industrial
Mounting
Surface Mount
Pin Count
324
Package Type
FBGA
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Number Of Gates
-
Lead Free Status / Rohs Status
Not Compliant
Other names
544-1041

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP1C20F324I7
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP1C20F324I7
Manufacturer:
ALTERA
0
Part Number:
EP1C20F324I7
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Company:
Part Number:
EP1C20F324I7
Quantity:
2 500
Part Number:
EP1C20F324I7N
Manufacturer:
ALTERA/31
Quantity:
318
Part Number:
EP1C20F324I7N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP1C20F324I7N
Manufacturer:
ALTERA
0
Altera Corporation
May 2008
Figure 2–10. LUT Chain and Register Chain Interconnects
The C4 interconnects span four LABs or M4K blocks up or down from a
source LAB. Every LAB has its own set of C4 interconnects to drive either
up or down.
LAB in a column. The C4 interconnects can drive and be driven by all
types of architecture blocks, including PLLs, M4K memory blocks, and
column and row IOEs. For LAB interconnection, a primary LAB or its
LAB neighbor can drive a given C4 interconnect. C4 interconnects can
drive each other to extend their range as well as drive row interconnects
for column-to-column connections.
Interconnect
Figure 2–11
Adjacent LE
Routing to
LUT Chain
Local
shows the C4 interconnect connections from a
Local Interconnect
Routing Among LEs
in the LAB
LE 10
LE 1
LE 2
LE 3
LE 4
LE 5
LE 6
LE 7
LE 8
LE 9
Register Chain
Routing to Adjacent
LE's Register Input
MultiTrack Interconnect
Preliminary
2–15

Related parts for EP1C20F324I7