101-0464 Rabbit Semiconductor, 101-0464 Datasheet - Page 21

no-image

101-0464

Manufacturer Part Number
101-0464
Description
COMPUTER SINGLE BOARD BL2130
Manufacturer
Rabbit Semiconductor
Datasheet

Specifications of 101-0464

Module/board Type
Single Board Computer Module
For Use With/related Products
BL2130
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
2.3 Starting Dynamic C
Once the BL2100 is connected to your PC and to a power source,
clicking on the Dynamic C
If you are using a USB port to connect your computer to the BL2100, choose
Project Options
tab. Click
2.4 Run a Sample Program
Use the
SAMPLES
window will open on your PC and will display a small square bouncing around in a box.
This program shows that the CPU is working. The sample program described in
Section 5.2.3, “Run the PINGME.C Demo,” tests the TCP/IP portion of the board.
2.4.1 Troubleshooting
If Dynamic C cannot find the target system (error message
Detected."
• Check that the BL2100 is powered correctly —
• Check both ends of the programming cable to ensure that they are firmly plugged into
• Ensure that the RabbitCore module is firmly and correctly installed in its connectors on
• Dynamic C uses the COM port specified during installation. Select a different COM
If Dynamic C appears to compile the BIOS successfully, but you then receive a communi-
cation error message when you compile and load a sample program, it is possible that your
PC cannot handle the higher program-loading baud rate. Try changing the maximum
download rate to a slower baud rate as follows.
• Locate the
User’s Manual
+RAW
the PC and the
ming port on the RabbitCore module with the marked (colored) edge of the program-
ming cable towards pin 1 of the programming header.
the BL2100 main board.
port within Dynamic C. From the
Communications
<Ctrl-Y>
unable to locate the target system, repeat the above steps until you locate the COM port
used by the programming cable.
menu. Select a slower Max download baud rate.
File
and
folder. Press function key
OK
to force Dynamic C to recompile the BIOS. If Dynamic C still reports it is
menu to open the sample program
):
.
Serial Options
GND
PROG
and select “Use USB to Serial Converter” under the
positions on screw-terminal header J5 (IDC header J4).
. Select another COM port from the list, then click OK. Press
icon on your desktop or in your
connector, not the
dialog in the Dynamic C
F9
Options
to compile and run the program. The
DIAG
menu, select
PONG.C
connector, is plugged in to the program-
the AC adapter should be plugged in
Options > Communications
, which is in the Dynamic C
Start
"No Rabbit Processor
Project Options
menu
start Dynamic C by double-
.
Communications
, then select
STDIO
Options >
to the
15

Related parts for 101-0464