MR62-48USRY NEC, MR62-48USRY Datasheet
MR62-48USRY
Specifications of MR62-48USRY
Related parts for MR62-48USRY
MR62-48USRY Summary of contents
Page 1
... As of May 2007, the MR62 series is being listed as a non-promotional item and is not for use in new designs. The MR62 series is a nonlatch type relay with 2 from c contact arrangements, and suitable for the switching of signals in telecommunications equipment, an industrial equipment, audio/visual sets, and so forth. ...
Page 2
... MAX. 9.8 (0.386) MAX. 5.08 7.62 0.65 (0.023) φ (0.30) Coil pin 9206 <1> Part number <4> <2> Manufacturer <3> Country of origin <4> Date code <5> UL, CSA marking <3> <5> 9206 <4> Data Sheet ER0515EJ1V0DS MR62 SERIES 7.62 (0.30) ...
Page 3
... Hz 6 Approx SAFETY STANDARD AND RATING UL Recognized (UL508)* File No E73266 30 Vdc (Resistive) 110 Vdc, 0.6 A (Resistive) 125 Vac (Resistive) *Spacing: UL114, UL478 Data Sheet ER0515EJ1V0DS MR62 SERIES MR62-**K*Y 1000 Vac *1 *1 1500 V surge *2 CSA Certificated (CSA C22.2 No14) File No LA46266 3 ...
Page 4
... Must Operate Voltage (Ω)±10% (Vdc) 62.5 3.5 90 4.2 202.5 6.3 360 8.4 1440 16.8 5760 34.4 Data Sheet ER0515EJ1V0DS MR62 SERIES (at 20°C) Must Release Voltage (Vdc) 0.25 0.33 0.45 0.68 1.3 2.6 (at 20°C) Must Release Voltage (Vdc) 0.25 0.33 0.45 ...
Page 5
... Must Operate Voltage (Ω)±10% (Vdc) 42 3.5 66 4.2 140 6.3 280 8.4 1050 16.8 4200 38.4 Data Sheet ER0515EJ1V0DS MR62 SERIES (at 20°C) Must Release Voltage (Vdc) 0.25 0.33 0.45 0.68 1.3 2.6 (at 20°C) Must Release Voltage (Vdc) 0.25 0.33 0.45 ...
Page 6
... Low power consumption type (UL recognized, CSA certified) Nominal Voltage Part Number (Vdc) MR62-5USRY 5 MR62-6USRY 6 MR62-9USRY 9 MR62-12USRY 12 MR62-24USRY 24 MR62-48USRY 48 High-breakdown voltage, low power consumption type (UL recognized, CSA certified) Nominal Voltage Part Number (Vdc) MR62-5KSRY 5 MR62-6KSRY 6 MR62-9KSRY 9 MR62-12KSRY 12 MR62-24KSRY 24 MR62-48KSRY 48 6 Coil Resistance Must Operate Voltage (Ω ...
Page 7
... Contact voltage (V) APPLIED VOLTAGE vs. TIMING MAX MIN 0.5 1.0 1.5 Applied power (W) RUNNING TEST (Nonload) Sample: MR62-5SR 20 pieces Driving dc, 50 Hz, 50% duty Operate voltage Relese voltage Operations (× RUNNING TEST (Load) Sample: MR62-5SR 10 pieces Load dc, 0.1 A Resistive ...
Page 8
... Dimension of Relay Tube (Unit: mm) 11.8 Outline of Package Rubber stopper (red) Rubber stopper (green) 8 Alternation of release voltage +40 +30 +20 +10 0 –10 –20 –30 – OFF OFF III IV OFF OFF OFF VI 25 pieces/tube Material: Polyvinyl chloride (anti-static treated) 534 Data Sheet ER0515EJ1V0DS MR62 SERIES Mounting layout 2.54 mm ...
Page 9
... Because the operating temperature range varies depending on the humidity, use the relay in the temperature range illustrated in the figure below. Prevent the relay from being frozen and avoid the generation of condensation max. Data Sheet ER0515EJ1V0DS MR62 SERIES 9 ...
Page 10
... The storage humidity must be no more than 70% RH. The recommended storage period is 3 months maximum store the relay for 3 months or longer, keep the storage humidity to within 50% RH. Do not store the relay for more than 6 months 100 Temperature (°C) Data Sheet ER0515EJ1V0DS MR62 SERIES (1,000 G) or more 2 ...
Page 11
... Special specifically designed for life support systems, life support systems or medical equipment for life support, etc. The quality grade of NEC devices is "Standard" unless otherwise specified in NEC's Data Sheets " " " " 3/01 MR62 SERIES DE0202 ...