IES5521ATR Hendon Semiconductors, IES5521ATR Datasheet

no-image

IES5521ATR

Manufacturer Part Number
IES5521ATR
Description
Board Mount Temperature Sensors 10mA Triac Temp control + Timer
Manufacturer
Hendon Semiconductors
Datasheet

Specifications of IES5521ATR

Package / Case
SO-8
Supply Voltage (max)
7.6 V
Supply Voltage (min)
6.3 V
Maximum Operating Temperature
+ 100 C
Minimum Operating Temperature
- 25 C
Supply Current
210 uA
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
1
• Time-out function stops triac operation after a set time
• Reset time-out by turning mains supply off and on
• Low external component count
• Constant ON period time, with proportional OFF time
• All ON periods are an integral number of mains cycles
• No DC component in the mains supply
• On chip circuit protection against triac gate spikes
• Low supply current requirement
• Sensor AC powered, thus minimising DC supply and
• Separate power supply input, allowing easy gate pulse
• Accurate time-out using the mains frequency, or widely
2
• Temperature control of cooking or heating appliances.
• Hair styling tools (straighteners, driers, curling wands ..)
• Electric Irons
• Toaster Ovens, Rice Cookers, Hotplates, Fry Pans, etc.
• Electric Blankets, Heating Pads, etc.
• or other appliances where a safety time-out is required.
4
© 2006 Integrated Electronic Solutions Pty Ltd. trading as
Hendon Semiconductors, all rights reserved.
2006 Sep 01, Revision 1.1
filtering needs
width adjustment
adjustable external “RC” time-out
@25°C
100k
NTC
FEATURES
TYPICAL APPLICATIONS
BLOCK DIAGRAM
θ
Rb
Ra
100k
RV1
SENS
C2
47uF
10V
4
IES5521A
100nF
C1
6
CAP
latch
Fig.1 Block diagram
Rtc
* If required
crossing
time-out
control
logic
zero
timer
5
RC
C3
1
Simple Zero-Crossing Triac Control
3
The IES5521A is a derivative of the OM1654A, but offering
the extra safety feature of a nominal 1 hour time-out. This
is a key safety requirement for a range of personal and
home appliance applications. The time-out function will
stop the triac operation and thus prevent power from being
applied to the heating elements.
Time-out can be accurately controlled from the AC supply
frequency for a period of 1 hour (60Hz, or 71minutes at
50Hz), or can be adjusted by adding external resistor and
capacitor components to set the frequency of an on-chip
RC oscillator. In this manner, time-out periods from 1
minute to more than 5 hours, are possible.
The IES5521A is a monolithic bipolar control circuit for
zero-crossing triggering of a triac in applications where it is
controlled by a resistive sensor such as an NTC
thermistor. In a typical application it can be used for the
temperature control of a heating element in a cooker or
another home heating appliance.
It is designed to control a suitable triac with a resistive load
ranging from 400 watts on a nominal 220/250 volt mains
supply. It can also be easily applied to 120Vac mains
applications.
Circuit with Adjustable Time-out
GATE
GENERAL DESCRIPTION
2
−6.5V
DC supply
stabalised
1
Vee
6.5V
Vcc
3
IES5521A-block cct4
8
7
Contents are subject to the Disclaimer
PWR
AC
Rd* 100k
Rc 0.25W
IES5521A
0.6W
330k
Product Specification
Neutral
Active
Load
Triac
BT134-600E
230Vac
mains

Related parts for IES5521ATR

IES5521ATR Summary of contents

Page 1

... C2 47uF 10V IES5521A Ra © 2006 Integrated Electronic Solutions Pty Ltd. trading as Hendon Semiconductors, all rights reserved. 2006 Sep 01, Revision 1.1 Simple Zero-Crossing Triac Control Circuit with Adjustable Time-out 3 GENERAL DESCRIPTION The IES5521A is a derivative of the OM1654A, but offering the extra safety feature of a nominal 1 hour time-out. This is a key safety requirement for a range of personal and home appliance applications ...

Page 2

PINNING INFORMATION 5.1 Pinning layout (8 pin GATE IES5521A SENS Fig.2 Pinning diagram (DIL-8 and SO-8) 6 FUNCTIONAL DESCRIPTION − Common, positive DC 6 supply The positive DC supply ...

Page 3

GATE − Triac gate drive 6.5 The triac gate drive output is designed to be connected directly to the triac gate without the need for an external current setting resistor. It has inbuilt protection to withstand transient signals which may ...

Page 4

For the application circuit of figure 6, the oscillation frequency ( OSC therefore: 1 ≈ -------------------------------- Hz OSC × × 1. The tolerance of the RC components determines the ...

Page 5

CHARACTERISTICS 25°C; Voltages are specified with respect to pin 3 (V amb SYMBOL PARAMETER Power supply −V supply voltage (operating) EE −I supply current (operating) EE Gate drive I gate current (triac GATE ...

Page 6

APPLICATION INFORMATION 9.1 Design considerations Figure 5 shows a typical simple circuit for a load of greater than 400W. In this application the PWR pin is not used. The power supply resistance of 160 kΩ sets the DC power ...

Page 7

Use of an input bridge circuit with gain will permit greater accuracy, and exhibit less ambient temperature dependence (for example by using one external transistor). These circuits still use an AC sensing circuit, and therefore do not provide ...

Page 8

Application circuits RV1 10 kΩ NTC1 10 θ kΩ Fig.5 IES5521A application diagram: 400 W resistive heating load, referenced to mains, R1 220 kΩ RV1 10 kΩ NTC1 10 θ kΩ R2 1kΩ C3 100nF 10V Fig.6 IES5521A application ...

Page 9

ORDERING INFORMATION TYPE NUMBER NAME IES5521A P DIP8 plastic dual in-line package; 8 leads (300 mil) IES5521A T SO8 plastic small outline package; 8 leads; body width 3.9 mm For more information on packages, please refer to the document ...

Page 10

... Exposure to limiting values for extended periods may affect device reliability. Application information Where application information is given advisory and does not form part of the specification. 14 COMPANY INFORMATION HENDON SEMICONDUCTORS a trading name of INTEGRATED ELECTRONIC SOLUTIONS PTY. LTD. ABN 17 080 879 616 Postal address: Hendon Semiconductors ...

Page 11

... Life Support Applications Products of Hendon Semiconductors (Hendon) are not designed for use in life support appliances, devices or systems, where malfunction can result in personal injury. Customers using or selling Hendon products for use in such applications their own risk and agree to fully indemnify Hendon for any damages resulting from such improper use or sale. ...

Related keywords