SI3215-B-FM Silicon Laboratories Inc, SI3215-B-FM Datasheet - Page 95

IC SLIC/CODEC SNGL-CH 38QFN

SI3215-B-FM

Manufacturer Part Number
SI3215-B-FM
Description
IC SLIC/CODEC SNGL-CH 38QFN
Manufacturer
Silicon Laboratories Inc
Type
SLIC/CODECr
Datasheet

Specifications of SI3215-B-FM

Package / Case
38-VFQFN, Exposed Pad
Data Interface
Serial
Resolution (bits)
16 b
Number Of Adcs / Dacs
1 / 1
Sigma Delta
No
Voltage - Supply, Analog
3.13 V ~ 5.25 V
Voltage - Supply, Digital
3.13 V ~ 5.25 V
Mounting Type
Surface Mount
Product
Telecom
Supply Current
3.3 V to 5 V
Maximum Operating Temperature
100 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
336-1287-5
Register 96. Calibration Control/Status Register 1
Reset settings = 0001_1111
Name
Type
Bit
Bit
7
6
5
4
3
2
1
0
Reserved
CALSP
Name
CALIL
CALR
CALD
CALC
CALT
D7
CAL
CAL
R/W
D6
Read returns zero.
Calibration Control/Status Bit.
Setting this bit begins calibration of the entire system.
0 = Normal operation or calibration complete.
1 = Calibration in progress.
Calibration Speedup.
Setting this bit shortens the time allotted for V
calibration cycle.
0 = 300 ms
1 = 30 ms
RING Gain Mismatch Calibration.
For use with discrete solution only. When using the Si3201, consult “AN35: Si321x
User’s Quick Reference Guide” and follow instructions for manual calibration.
0 = Normal operation or calibration complete.
1 = Calibration enabled or in progress.
TIP Gain Mismatch Calibration.
For use with discrete solution only. When using the Si3201, consult “AN35: Si321x
User’s Quick Reference Guide” and follow instructions for manual calibration.
0 = Normal operation or calibration complete.
1 = Calibration enabled or in progress.
Differential DAC Gain Calibration.
0 = Normal operation or calibration complete.
1 = Calibration enabled or in progress.
Common Mode DAC Gain Calibration.
0 = Normal operation or calibration complete.
1 = Calibration enabled or in progress.
I
0 = Normal operation or calibration complete.
1 = Calibration enabled or in progress.
LIM
Calibration.
CALSP
R/W
D5
CALR
R/W
D4
Rev. 0.92
CALT
R/W
D3
Function
CALD
R/W
BAT
D2
settling at the beginning of the
CALC
R/W
D1
CALIL
R/W
D0
Si3215
95