Page 1
E Prepared (also subject responsible if other) EWEIXIE Approved Prepared (also subject responsible if other) PKB4000C series EZHEWNG SEC/D (Julia You) DC/DC converters, Input 36-75 V, Output 60A/144W Approved Key Features • Industry standard low profile Eighth-brick 58.4 x 22.7 ...
Page 2
... Warranty period and conditions are defined in Ericsson Power Modules General Terms and Conditions of Sale. Limitation of Liability Ericsson Power Modules does not make any other warranties, expressed or implied including any warranty of merchantability or fitness for a particular purpose (including, but not limited to, use in life support applications, where malfunctions of product can cause injury to a person’ ...
Page 3
... ETS300132-2 “Power supply interface at the input to telecommunications equipment; part 2: DC”, but all of these standards are based on IEC/EN/UL60950 with regards to safety. Ericsson Power Modules DC/DC converters and DC/DC regulators are UL60950 recognized and certified in accordance with EN60950. The flammability rating for all construction parts of the products meets requirements for V-0 class material according to IEC 60695-11-10 ...
Page 4
E Prepared (also subject responsible if other) ESHUHAN Approved PKB4000C series SEC/D (Betty Wu) DC/DC converters, Input 36-75 V, Output 60A/144W Absolute Maximum Ratings Characteristics T Operating Temperature (see Thermal Consideration section Storage temperature S V Input voltage ...
Page 5
E Prepared (also subject responsible if other) ESHUHAN Approved PKB4000C series SEC/D (Betty Wu) DC/DC converters, Input 36-75 V, Output 60A/144W 1.2 V/60 A Electrical Specification T = -40 to +90º sense pins connected ...
Page 6
E Prepared (also subject responsible if other) ESHUHAN Approved PKB4000C series SEC/D (Betty Wu) DC/DC converters, Input 36-75 V, Output 60A/144W 1.2 V/60 A Typical Characteristics Efficiency [%] Efficiency ...
Page 7
E Prepared (also subject responsible if other) ESHUHAN Approved PKB4000C series SEC/D (Betty Wu) DC/DC converters, Input 36-75 V, Output 60A/144W 1.2 V/60 A Typical Characteristics Start-up Start-up enabled by connecting V at: Top trace: output voltage (0.5 V/div.). I ...
Page 8
E Prepared (also subject responsible if other) ESHUHAN Approved PKB4000C series SEC/D (Betty Wu) DC/DC converters, Input 36-75 V, Output 60A/144W 1.2 V/60 A Typical Characteristics Output Current Derating – Open frame [ ...
Page 9
E Prepared (also subject responsible if other) ESHUHAN Approved PKB4000C series SEC/D (Betty Wu) DC/DC converters, Input 36-75 V, Output 60A/144W 1.5 V/60 A Electrical Specification T = -40 to +90º sense pins connected ...
Page 10
E Prepared (also subject responsible if other) ESHUHAN Approved PKB4000C series SEC/D (Betty Wu) DC/DC converters, Input 36-75 V, Output 60A/144W 1.5 V/60 A Typical Characteristics Efficiency [%] Efficiency ...
Page 11
E Prepared (also subject responsible if other) ESHUHAN Approved PKB4000C series SEC/D (Betty Wu) DC/DC converters, Input 36-75 V, Output 60A/144W 1.5 V/60 A Typical Characteristics Start-up Start-up enabled by connecting V at: Top trace: output voltage (1.0 V/div.). I ...
Page 12
E Prepared (also subject responsible if other) ESHUHAN Approved PKB4000C series SEC/D (Betty Wu) DC/DC converters, Input 36-75 V, Output 60A/144W 1.5 V/60 A Typical Characteristics Output Current Derating – Open frame [ ...
Page 13
E Prepared (also subject responsible if other) ESHUHAN Approved PKB4000C series SEC/D (Betty Wu) DC/DC converters, Input 36-75 V, Output 60A/144W 1.8 V/60 A Electrical Specification T = -40 to +90º sense pins connected ...
Page 14
E Prepared (also subject responsible if other) ESHUHAN Approved PKB4000C series SEC/D (Betty Wu) DC/DC converters, Input 36-75 V, Output 60A/144W 1.8 V/60 A Typical Characteristics Efficiency [%] Efficiency ...
Page 15
E Prepared (also subject responsible if other) ESHUHAN Approved PKB4000C series SEC/D (Betty Wu) DC/DC converters, Input 36-75 V, Output 60A/144W 1.8 V/60 A Typical Characteristics Start-up Start-up enabled by connecting V at: Top trace: output voltage (1.0 V/div.). I ...
Page 16
E Prepared (also subject responsible if other) ESHUHAN Approved PKB4000C series SEC/D (Betty Wu) DC/DC converters, Input 36-75 V, Output 60A/144W 1.8 V/60 A Typical Characteristics Output Current Derating – Open frame [ ...
Page 17
E Prepared (also subject responsible if other) ESHUHAN Approved PKB4000C series SEC/D (Betty Wu) DC/DC converters, Input 36-75 V, Output 60A/144W 3.3 V/40 A Electrical Specification T = -40 to +90º sense pins connected ...
Page 18
E Prepared (also subject responsible if other) ESHUHAN Approved PKB4000C series SEC/D (Betty Wu) DC/DC converters, Input 36-75 V, Output 60A/144W 3.3 V/40 A Typical Characteristics Efficiency [%] ...
Page 19
E Prepared (also subject responsible if other) ESHUHAN Approved PKB4000C series SEC/D (Betty Wu) DC/DC converters, Input 36-75 V, Output 60A/144W 3.3 V/40 A Typical Characteristics Start-up Start-up enabled by connecting V at: Top trace: output voltage (1 V/div.). I ...
Page 20
E Prepared (also subject responsible if other) ESHUHAN Approved PKB4000C series SEC/D (Betty Wu) DC/DC converters, Input 36-75 V, Output 60A/144W 3.3 V/40 A Typical Characteristics Output Current Derating – Open frame [ ...
Page 21
E Prepared (also subject responsible if other) ESHUHAN Approved PKB4000C series SEC/D (Betty Wu) DC/DC converters, Input 36-75 V, Output 60A/144W 5.0 V/28 A Electrical Specification T = -40 to +90º sense pins connected ...
Page 22
E Prepared (also subject responsible if other) ESHUHAN Approved PKB4000C series SEC/D (Betty Wu) DC/DC converters, Input 36-75 V, Output 60A/144W 5.0 V/28 A Typical Characteristics Efficiency [%] ...
Page 23
E Prepared (also subject responsible if other) ESHUHAN Approved PKB4000C series SEC/D (Betty Wu) DC/DC converters, Input 36-75 V, Output 60A/144W 5.0 V/28 A Typical Characteristics Start-up Start-up enabled by connecting V at: Top trace: output voltage (2 V/div.). I ...
Page 24
E Prepared (also subject responsible if other) ESHUHAN Approved PKB4000C series SEC/D (Betty Wu) DC/DC converters, Input 36-75 V, Output 60A/144W 5.0 V/28 A Typical Characteristics Output Current Derating – Open frame [ ...
Page 25
E Prepared (also subject responsible if other) ESHUHAN Approved PKB4000C series SEC/D (Betty Wu) DC/DC converters, Input 36-75 V, Output 60A/144W 12 V/12 A Electrical Specification T = -40 to +90º sense pins connected ...
Page 26
E Prepared (also subject responsible if other) ESHUHAN Approved PKB4000C series SEC/D (Betty Wu) DC/DC converters, Input 36-75 V, Output 60A/144W 12 V/12 A Typical Characteristics Efficiency [%] Efficiency ...
Page 27
E Prepared (also subject responsible if other) ESHUHAN Approved PKB4000C series SEC/D (Betty Wu) DC/DC converters, Input 36-75 V, Output 60A/144W 12 V/12 A Typical Characteristics Start-up Start-up enabled by connecting V at: Top trace: output voltage (5 V/div.). I ...
Page 28
E Prepared (also subject responsible if other) ESHUHAN Approved PKB4000C series SEC/D (Betty Wu) DC/DC converters, Input 36-75 V, Output 60A/144W 12 V/12 A Typical Characteristics Output Current Derating – Open frame [ ...
Page 29
E Prepared (also subject responsible if other) ESHUHAN Approved PKB4000C series DC/DC converters, Input 36-75 V, Output 60A/144W EMC Specification Conducted EMI measured according to EN55022, CISPR 22 and FCC part 15J (see test set-up). See Design Note 009 for ...
Page 30
E Prepared (also subject responsible if other) ESHUHAN Approved PKB4000C series DC/DC converters, Input 36-75 V, Output 60A/144W Operating information Input Voltage The input voltage range 36 to 75Vdc meets the requirements of the European Telecom Standard ETS 300 132-2 ...
Page 31
E Prepared (also subject responsible if other) ESHUHAN Approved PKB4000C series DC/DC converters, Input 36-75 V, Output 60A/144W Operating information continued Parallel Operation Two converters may be paralleled for redundancy if the total max not recommended to power ...
Page 32
E Prepared (also subject responsible if other) ESHUHAN Approved PKB4000C series DC/DC converters, Input 36-75 V, Output 60A/144W Thermal Consideration General The converters are designed to operate in different thermal environments and sufficient cooling must be provided to ensure reliable ...
Page 33
E Prepared (also subject responsible if other) ESHUHAN Approved PKB4000C series DC/DC converters, Input 36-75 V, Output 60A/144W Connections Top view Pin Designation Function 1 +In Positive input 2 RC Remote control 3 -In Negative input 4 -Out Negative output ...
Page 34
E Prepared (also subject responsible if other) EPANHON Approved PKB4000C series SEC/D [Julia You] DC/DC converters, Input 36-75 V, Output 60A/144W Mechanical Information - Surface Mount Version Ericsson Internal PRODUCT SPEC. MECHANICAL No. 4/1301-BMR 655 Uen Technical Specification Checked Date ...
Page 35
E Prepared (also subject responsible if other) EPANHON Approved PKB4000C series SEC/D [Julia You] DC/DC converters, Input 36-75 V, Output 60A/144W Mechanical Information - Through Hole Mount — Open Frame Version Ericsson Internal PRODUCT SPEC. MECHANICAL No. 4/1301-BMR 655 Uen ...
Page 36
E Prepared (also subject responsible if other) EPANHON Approved PKB4000C series SEC/D [Julia You] DC/DC converters, Input 36-75 V, Output 60A/144W Mechanical Information — Through Hole Mount — Base Plate Version Ericsson Internal PRODUCT SPEC. MECHANICAL No. 4/1301-BMR 655 Uen ...
Page 37
E Prepared (also subject responsible if other) MICJAN Approved PKB4000C series MPM/BK/P [Natalie Johansson] DC/DC converters, Input 36-75 V, Output 60A/144W Soldering Information - Surface Mounting The surface mount version of the product is intended for convection or vapor phase ...
Page 38
E Prepared (also subject responsible if other) MICJAN Approved PKB4000C series MPM/BK/P [Natalie Johansson] DC/DC converters, Input 36-75 V, Output 60A/144W Soldering Information — Through Hole Mounting The through hole mount version of the product is intended for manual or ...
Page 39
E Prepared (also subject responsible if other) MICJAN Approved PKB4000C series MPM/BK/P [Natalie Johansson] DC/DC converters, Input 36-75 V, Output 60A/144W Product Qualification Specification Characteristics External visual inspection IPC-A-610 Change of temperature IEC 60068-2-14 Na (Temperature cycling) Cold (in operation) ...