Specifications of NED-50B

Product
Switching
Commercial/medical
Commercial
Output Power Rating
20 W
Input Voltage
85 VAC to 264 VAC, 120 VDC to 370 VDC
Number Of Outputs
2
Output Voltage (channel 1)
5 V
Output Current (channel 1)
4 A
Output Voltage (channel 2)
24 V
Output Current (channel 2)
1.4 A
Mounting Style
Chassis
Output Type
DC
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
SPECIFICATION
MODEL
OUTPUT
INPUT
PROTECTION
ENVIRONMENT
SAFETY &
EMC
(Note 7)
OTHERS
NOTE
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVERLOAD
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
HARMONIC CURRENT
EMS IMMUNITY
MTBF
DIMENSION
PACKING
OUTPUT NUMBER
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
RIPPLE & NOISE (max.)
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY(Typ.)
AC CURRENT (Typ.)
EMI CONDUCTION & RADIATION
50W Dual Output Switching Power Supply
Note.4
Note.5
Note.3
Note.6
Note.2
NED-50A
5V
6A
1 ~ 6A
54W
80mVp-p
CH1: 4.75 ~ 5.5V
CH1
500ms, 30ms/230VAC
50ms/230VAC
85 ~ 264VAC
47 ~ 63Hz
0.44Kg; 45pcs/21Kg/1.24CUFT
79%
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
CH1: 5.75 ~ 6.75V
Protection type : Shut down o/p voltage, re-power on to recover
-20 ~ +60
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, CB(IEC60950-1) approved
I/P-O/P:3KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2, 3, 4, 5, 6, 8,11, ENV50204, EN55024, EN61000-6-1, light industry level, criteria A
413.3K hrs min.
129*98*38mm (L*W*H)
1.1A/115VAC
COLD START 45A
<2mA / 240VAC
2.0%
0.5%
1.5%
0.03%/
(0 ~ 45 )
(Refer to output load derating curve)
120 ~ 370VDC
I/P-FG:1.5KVAC
MIL-HDBK-217F (25 )
0.65A/230VAC
10ms/115VAC at full load
1200ms, 30ms/115VAC at full load
CH2
12V
2A
0.3 ~ 3A
120mVp-p
6.0%
1.0%
3.0%
O/P-FG:0.5KVAC
NED-50B
CH1
5V
4A
1 ~ 6A
53.6W
80mVp-p
CH1: 4.75 ~ 5.5V
82%
2.0%
0.5%
1.5%
N E D - 5 0
File Name:NED-50-SPEC 2010-10-18
CH2
24V
1.4A
0.2 ~ 2A
200mVp-p
6.0%
1.0%
3.0%
s e r i e s

Related parts for NED-50B

NED-50B Summary of contents

Page 1

... I/P-FG:1.5KVAC O/P-FG:0.5KVAC MIL-HDBK-217F ( NED-50B CH1 CH2 5V 24V 53.6W 80mVp-p 200mVp-p CH1: 4.75 ~ 5.5V 2.0% 6.0% 0.5% 1.0% 1.5% 3 ...

Page 2

... Output Derating VS Input Voltage 100 (HORIZONTAL Case No. 903 122.5 129 120 77 fosc : 60KHz RECTIFIERS +V2 & FILTER RECTIFIERS +V1 & COM FILTER DETECTION CIRCUIT O.V.P. 100 115 120 140 160 180 200 220 240 INPUT VOLTAGE (VAC) 60Hz File Name:NED-50-SPEC 2010-10- Unit:mm Ta=25 264 ...

Related keywords