NED-100D Mean Well, NED-100D Datasheet

Linear & Switching Power Supplies 24V/3.5A 5V/3A 99W

NED-100D

Manufacturer Part Number
NED-100D
Description
Linear & Switching Power Supplies 24V/3.5A 5V/3A 99W
Manufacturer
Mean Well
Series
NED 100r
Datasheet

Specifications of NED-100D

Product
Switching
Commercial/medical
Commercial
Output Power Rating
84 W
Input Voltage
88 VAC to 132 VAC, 248 VDC to 373 VDC
Number Of Outputs
2
Output Voltage (channel 1)
24 V
Output Current (channel 1)
3.5 A
Output Voltage (channel 2)
5 V
Output Current (channel 2)
3 A
Mounting Style
Chassis
Dimensions
199 mm L x 98 mm W x 38 mm H
Output Type
DC
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
SPECIFICATION
MODEL
OUTPUT
INPUT
PROTECTION
ENVIRONMENT
SAFETY &
EMC
(Note 7)
OTHERS
NOTE
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVER LOAD
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
HARMONIC CURRENT
EMS IMMUNITY
MTBF
DIMENSION
PACKING
OUTPUT NUMBER
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
RIPPLE & NOISE (max.)
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
EMI CONDUCTION & RADIATION
100W Dual Output Switching Power Supply
Note.4
Note.5
Note.3
Note.6
Note.2
CH1: 4.75 ~ 5.5V
NED-100A
5V
10A
2 ~ 10A
100.4W
80mVp-p
CH1
2000ms, 30ms/230VAC
25ms/230VAC
88 ~ 132VAC / 176 ~ 264VAC selected by switch
47 ~ 63Hz
199*98*38mm (L*W*H)
80%
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
CH1: 5.75 ~ 6.75V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-20 ~ +60
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, CB(IEC60950-1) Approved
I/P-O/P:3KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2, 3, 4, 5, 6, 8,11, ENV50204, EN55024,EN61000-6-1,light industry level, criteria A
320.7K hrs min.
2A/115VAC
COLD START 45A
<2mA / 240VAC
0.55Kg; 30pcs/17.5Kg/0.97CUFT
2.0%
0.5%
1.0%
0.03%/
(0 ~ 50 )on Ch1 output
(Refer to output load derating curve)
CH2
12V
4.2A
0.7 ~ 7.0A
120mVp-p
10%
0.5%
5.0%
1.2A/230VAC
I/P-FG:1.5KVAC
MIL-HDBK-217F (25 )
20ms/115VAC at full load
1200ms, 30ms/115VAC at full load
CH1: 4.75 ~ 5.5V
NED-100B
CH1
5V
8A
1 ~ 10A
100W
80mVp-p
CH2: 5.75 ~ 6.75V
82%
2.0%
0.5%
1.0%
O/P-FG:0.5KVAC
CH2
24V
2.5A
0.3 ~ 3.5A
200mVp-p
8.0%
0.5%
4.0%
248 ~ 373VDC
CH1: 11.4 ~ 13.2V
NED-100C
12V
7A
0 ~ 8A
99W
120mVp-p
CH1
CH1: 13.8 ~ 15.8V
80%
2.0%
0.5%
1.0%
N E D - 1 0 0
CH2
5V
3A
0 ~ 3A
80mVp-p
3.0%
0.5%
2.0%
NED-100D
CH1
24V
3.5A
0 ~ 4A
99W
120mVp-p
CH1: 22.8 ~ 26.4V
CH2: 27.6 ~ 32.4V
82%
File Name:NED-100-SPEC 2008-09-25
2.0%
0.5%
1.0%
CH2
5V
3A
0 ~ 3A
80mVp-p
3.0%
0.5%
2.0%
s e r i e s

Related parts for NED-100D

NED-100D Summary of contents

Page 1

... CH2: 5.75 ~ 6.75V (Refer to output load derating curve) 0.03 )on Ch1 output I/P-FG:1.5KVAC O/P-FG:0.5KVAC MIL-HDBK-217F ( NED-100C NED-100D CH1 CH2 CH1 12V 5V 24V 99W 99W 120mVp-p 80mVp-p 120mVp-p CH1: 11.4 ~ 13.2V CH1: 22 ...

Page 2

... Terminal Pin No. Assignment Pin No. Assignment Pin No AC/N 4 & FILTER & FILTER DETECTION CIRCUIT O.V.P. 95 100 115 120 190 200 230 240 INPUT VOLTAGE (VAC) 60Hz File Name:NED-100-SPEC 2008-09- Unit:mm Assignment DC OUTPUT +V2 DC OUTPUT COM DC OUTPUT +V1 fosc : 55KHz +V2 +V1 COM Ta=25 132 264 ...

Related keywords