T-50B Mean Well, T-50B Datasheet

Linear & Switching Power Supplies 49W 5V 5A 12V 1A -12V 1A

T-50B

Manufacturer Part Number
T-50B
Description
Linear & Switching Power Supplies 49W 5V 5A 12V 1A -12V 1A
Manufacturer
Mean Well
Datasheet

Specifications of T-50B

Product
Switching
Commercial/medical
Commercial
Output Power Rating
25 W
Input Voltage
86 VAC to 264 VAC, 240 VDC to 370 VDC
Number Of Outputs
3
Output Voltage (channel 1)
5 V
Output Current (channel 1)
5 A
Output Voltage (channel 2)
12 V
Output Current (channel 2)
1 A
Output Voltage (channel 3)
- 12 V
Output Current (channel 3)
1 A
Mounting Style
Chassis
Output Type
DC
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
SPECIFICATION
MODEL
OUTPUT
INPUT
PROTECTION
ENVIRONMENT
SAFETY &
EMC
OTHERS
NOTE
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVER LOAD
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
MTBF
DIMENSION
PACKING
OUTPUT NUMBER
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
RIPPLE & NOISE (max.)
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
50W Triple Output Switching Power Supply
Note.3
Note.2
T-50A
CH1
5V
7A
0.6 ~ 7A 0.2 ~ 1A 0.2 ~ 1A
52W
100mVp-p 100mVp-p 100mVp-p
CH1:4.75 ~ 5.5V
200ms, 100ms at full load
16ms at full load
85 ~ 132VAC/170 ~ 264VAC selected by switch
47 ~ 63Hz
470.2K hrs min.
105 ~ 150% rated output power
Protection type : Fold back current limiting, recovers automatically after fault condition is removed
20 ~ 90% RH non-condensing
-10 ~ +65
-20 ~ +85 , 10 ~ 95% RH
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
Design refer to UL1012
I/P-O/P:1.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
159*97*38mm (L*W*H)
66%
1.6A/115VAC
COLD START 20A/115VAC
<0.5mA / 240VAC
0.54Kg; 24pcs/14Kg/0.75CUFT
2.0%
0.5%
1.0%
0.03%/
CH2
12V
1A
(0 ~ 50 )on +5V output
5.0%
0.5%
4.0%
(Refer to output load derating curve), 20 ~ 90% RH
MIL-HDBK-217F (25 )
0.8A/230VAC
I/P-FG:1.5KVAC
CH3
-5V
1A
5.0%
0.5%
4.0%
T-50B
49W
CH1:4.75 ~ 5.5V
CH1
5V
5A
0.6 ~ 5A
100mVp-p
69%
40A/230VAC
2.0%
0.5%
1.0%
O/P-FG:0.5KVAC
CH2
12V
1A
0.2 ~ 1A
100mVp-p
5.0%
0.5%
4.0%
240 ~ 370VDC
CH3
-12V
1A
0.2 ~ 1A
100mVp-p
5.0%
0.5%
4.0%
T-50C
50W
CH1:4.75 ~ 5.5V
CH1
5V
4A
0.6 ~ 4A
100mVp-p
71%
2.0%
0.5%
1.0%
CH2
15V
1A
0.2 ~ 1A
100mVp-p
5.0%
0.5%
4.0%
CH3
-15V
1A
0.2 ~ 1A
100mVp-p
5.0%
0.5%
4.0%
T- 5 0
T-50D
51W
200ms, 80ms at full load
CH1
5V
3A
0.6 ~ 4A
50mVp-p
CH1:4.75 ~ 5.5V
72%
2.0%
0.5%
1.0%
File Name:T-50-SPEC 2005-09-06
CH2
12V
1A
0.2 ~ 1.2A 0.2 ~ 1.2A
120mVp-p 120mVp-p
6.0%
1.0%
5.0%
s e r i e s
CH3
24V
1A
6.0%
1.0%
5.0%

Related parts for T-50B

T-50B Summary of contents

Page 1

... axes SAFETY STANDARDS Design refer to UL1012 SAFETY & WITHSTAND VOLTAGE I/P-O/P:1.5KVAC EMC ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC MTBF 470.2K hrs min. OTHERS DIMENSION 159*97*38mm (L*W*H) 0.54Kg; 24pcs/14Kg/0.75CUFT PACKING NOTE T-50B CH2 CH3 CH1 CH2 12V -5V 5V 12V 0 0 49W 100mVp-p 100mVp-p CH1:4 ...

Page 2

... DC OUTPUT +V1 Static Characteristics (B) 13 5.2 12 5.0 11 4.8 10 4.6 9 4.4 8 4 (VERTICAL) 60 (HORIZONTAL) 55 120 Case No. 901 MODEL T-50A T-50B T-50C T-50D Pin No. 4 -5V -12V -15V +24V +12V +5V +12V -12V 100 105 110 115 120 125 170 180 190 200 210 220 ...

Related keywords