AT-FM-10K BANNER ENGINEERING, AT-FM-10K Datasheet - Page 3

no-image

AT-FM-10K

Manufacturer Part Number
AT-FM-10K
Description
Control Module, Two Hand; Solid State (NPN, PNP), Relay (Auxiliary N.C.); 200 W
Manufacturer
BANNER ENGINEERING
Type
Safetyr
Datasheets

Specifications of AT-FM-10K

Brand/series
Duo-Touch
Contact Form
SPDT-NO/NC
Dimensions
22.5mmW×84mmH×118mmD
Enclosure Rating
IP20
Indicator
4 Green LED, 1 Red LED
Ip Rating
IP20
Material, Casing
Polycarbonate
Mounting
DIN Rail
Mounting Type
DIN Rail
Number Of Outputs
4
Output Type
Digital/Relay
Power Consumption
200 W
Primary Type
Controller
Standards
cULus, cCSAus, CE
Temperature, Operating
0 to +50 °C
Voltage, Supply
24 VDC
Coil Voltage Vac Nom
24V
Coil Voltage Vdc Nom
24V
Contact Current Max
6A
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
24V
Contact Configuration
SPST-NO
No. Of Poles
1
Lead Free Status / Rohs Status
RoHS Exempt Product
For Use With
Two-Hand Control
Supply Voltage and Current
Supply Protection Circuitry
Output Configuration
Output Response Time
Input Requirements
Simultaneity Monitoring
Period
Status Indicators
Housing
Mounting
Vibration Resistance
Operating Conditions
Dimensions
Safety Category
Certifications
DUO-TOUCH
Protected against transient voltages and reverse polarity
Each normally open output channel is a series connection of contacts from two forced-guided (positive-
guided) relays, K1-K2.
Contacts: AgNi, 5 µm gold-plated
Low Current Rating:
Caution: The 5 µm gold-plated contacts allow the switching of low current/low voltage. In these low-
To preserve the gold plating on the contacts, the following max. values should not be exceeded at any time:
High Current Rating:
If higher loads must be switched through one or more of the contacts, the minimum and maximum values
of the contact(s) changes to:
Mechanical life: 50,000,000 operations
Electrical life: 150,000 operations typical, @ 200 W (1,500 VA) switched power, resistive load.
Note: Transient suppression is recommended when switching inductive loads. Install suppressors
35 milliseconds maximum ON and OFF
Outputs from actuating devices must each be capable of switching up to 20 mA @ 12V dc.
≤ 500 milliseconds
4 green LED indicators:
Power ON
Input 1 energized
Input 2 energized
Output
Polycarbonate. Rated NEMA 1 (IEC IP20)
Mounts to standard 35 mm DIN rail track. Safety Module must be installed inside an enclosure rated
NEMA 3 (IEC IP54), or better.
10 to 55 Hz @ 0.35 mm displacement per IEC 68-2-6
Temperature: 0° to +50°C (+32° to 122°F)
Maximum Relative Humidity: 90% @ +50°C (non-condensing)
Heat Dissipation Considerations: See page 4.
See Figure 5.
4 per ISO 13849-1; Type IIIC per ISO 13851 (EN574) (when used with STBs or hard contacts)
24V ac/dc ±15% @ 150 mA
Min. voltage: 1V ac/dc
Min. current: 5 mA ac/dc
Min. power: 5 mW (5 mVA)
Min. voltage: 15V ac/dc
Min. current: 250 mA ac/dc
Min. power: 5 W (5 VA)
across load. Never install suppressors across output contacts (see Warning, page 7).
power applications, multiple contacts can also be switched in series (e.g., “dry switching”).
®
C
SG –
Specifications
R
US
Model AT-FM-10K Two-Hand Control Module
Max. voltage: 60V
Max. current: 300 mA
Max. power: 7 W (7 VA)
Max. voltage: 250V ac/dc
Max. current: 6 A
Max. power: 200 W (1,500 VA)
1 red LED indicator:
Fault
P/N 64137 rev. C
11

Related parts for AT-FM-10K