S070-14A-10 SMC Corporation, S070-14A-10 Datasheet - Page 2

no-image

S070-14A-10

Manufacturer Part Number
S070-14A-10
Description
Plug connector assy, 1000mm
Manufacturer
SMC Corporation
Datasheet
Flow Specifications/Response Time
Base mounted
JIS Symbol
with power saving circuit
Note 1) With the 0.1 W DC specification, keep the vibration/impact within10/50 m/s
Note 2) The response time is the value at the rated voltage and maximum operating pressure.
0.1 W DC (at holding)
Power consumption
0.35 W DC
0.5 W DC
0.35 W DC at inrush (20 ms) and 0.1 W DC at holding.
Body ported
Note 1)
Maximum operating
pressure
0.5 MPa
0.3 MPa
0.3 MPa
0.1 MPa
0.3 MPa
0.1 MPa
Specifications
Solenoid Specifications
Power consumption
Rated coil voltage
Allowable voltage fluctuation
Coil insulation type
Valve construction
Fluid
Maximum operating pressure
Proof pressure
Ambient and fluid temperature
Lubrication
Impact/Vibration resistance
Enclosure
Weight
Mounting orientation
Note 1) Use dry air and prevent condensation at low temperatures.
Note 2) Vibration resistance: No malfunction resulted in 45 to 2000 Hz, a one-sweep test performed in
Note 3) With the low vacuum specification, the operating pressure range is 1.33 × 10
Note 1) With a light/surge voltage suppressor and power saving circuit, the light consumes a power
Note 2) With a power saving circuit, keep the voltage fluctuation within 24 VDC ± 5%.
Impact resistance:
With the 0.1 W specification, the vibration and impact resistance is 10/50 m/s
operating pressure.
equivalent to 2 mA.
C[dm
0.042
0.083
0.042
0.083
0.021
0.042
3
/(s
Note 1)
·
bar)]
Compact Direct Operated
Note 2)
Flow characteristics
Note 2)
3 Port Solenoid Valve
Note 1)
the axial and right angle directions of the main valve and armature for both
energized and de-energized states.
No malfunction resulted in an impact test using a drop impact tester. The
test was performed one time each in the axial and right angle directions of
the main valve and armature, for both energized and de-energized states.
2
.
0.27
0.28
0.27
0.28
0.27
0.28
b
0.35 W (Standard), 0.5 W (High voltage), 0.1 W (Holding)
0.3 MPa (0.35 W, 0.1 W), 0.5 MPa (0.5 W)
Air/Inert gas/Low vacuum (1.33 x 10
0.011
0.021
0.011
0.021
0.006
0.011
Cv
±10% of the rated voltage
5 g (Single unit valve)
Equivalent to class B
3, 5, 6, 12, 24 VDC
Not required
–10 to 50°C
30/150 m/s
Poppet
1 MPa
IP40
Free
Series
3 or less
5 or less
3 or less
5 or less
3 or less
5 or less
Response time ms
ON
2
2
2
Pa to the maximum
or less.
2
Pa)
S070
3 or less
3 or less
3 or less
3 or less
6 or less
6 or less
OFF
Note 2)
4-11-3
V100
SY
SYJ
VK
VZ
VT
VP
VG
VP
S070
VQ
VKF
VQZ
VZ
VS
VFN

Related parts for S070-14A-10