DSO1024A Agilent Technologies Test Equipment, DSO1024A Datasheet - Page 9

no-image

DSO1024A

Manufacturer Part Number
DSO1024A
Description
Oscilloscope, 4 Channels, 200 MHz
Manufacturer
Agilent Technologies Test Equipment
Type
Digitalr
Datasheet

Specifications of DSO1024A

Bandwidth
200 MHz
Bandwidth Limit
20 MHz
Bandwidth, 3 Db
200 MHz
Brand/series
DSO 1000 Series
Configuration
Bench/Portable
Dimensions
12.78 × 6.21 × 5.08 In. (W × H × D)
Display Type
Color TFT LCD
Gain, Voltage
2 mV/div to 5 mV/div: ±4% full scale10 mV/div to 5 mV/div: ±3% full scale
Input Impedance
1 MΩ ±1% in parallel with 18 pF ±3 pF
Memory
20 Kpts
Number Of Channels
4
Sample Rate
2 GS/s
Performance characteristics
Acquisition modes
Interpolation
Trigger coupling
Trigger modes
Trigger source
Trigger sensitivity
Cursor measurement
Auto measurement
Display all measurements
Math functions
AutoScale
Display
Waveform update rate
Save/Recall internal
Save/Recall external
1
Normal
Averaging
Sequence
Peak detect
Roll
Force
Edge
Video
Pulse width
Alternate
Voltage
Time
Counter
Display persistence
Display types
Denotes warranted specifications, all others are typical. Specifications are valid after a 30-minute warm-up period and ±10°C from firmware calibration temperature.
1
Displays sampled data directly to the screen in real time
Selectable from 2, 4, 8,16, 32, 64, 128 or 256
Selectable 1 to 1,000 acquisition frames can be recorded, played back and stored in the scope memory or
external USB memory
Captures high-frequency glitches as narrow as 10 nsec when viewing signals at slow sweep speeds
(slower than 5 μsec/div)
Waveform display rolls from left to right. Minimum horizontal scale setting is 50 msec/div.
Sinx/x
AC, DC, LF reject
Triggers immediately when front panel button is pressed
Triggers on the positive or negative slope on any channel
Triggers on NTSC, PAL or SECAM video signals
Triggers on pulse width greater than, equal to or less than a specific time limit, ranging from 20 nsec
to 10 sec
Triggers on two non-synchronized active channels
2-channel models: Ch 1, 2, Ext, Ext/5, AC Line (edge only)
4-channel models: Ch 1, 2, 3, 4, Ext, Ext/5, AC Line (edge only)
≥5 mV/div: 1 div from DC to 10 MHz, 1.5 div from 10 MHz to full bandwidth
<5 mV/div: 1 div from DC to 10 MHz, 1.5 div from 10 MHz to 20 MHz
Manual, track waveform or automatic measurement selections. Manual and track waveform selections
provide readout of Horizontal (X, ΔX, 1/ΔY) and Vertical (Y, ΔY)
Maximum, minimum, peak-to-peak, top, base, amplitude, average, RMS, overshoot, preshoot
Period, frequency, rise time, fall time, + width, - width, +duty cycle, -duty cycle, delay A-->B (rising edge),
delay A-->B (falling edge), phase A-->B (rising edge) and phase A-->B (falling edge)
Integrated 6-digit frequency counter on any channel. Counts up to the scope’s bandwidth (200 MHz max)
Mode to display all single-channel automatic measurements simultaneously on the display
A+B, A-B, AxB, FFT
Source channel selection for A and B can be any combination of oscilloscope channels 1 and 2
(or 3 and 4 on DSO1xx4A).
Finds and displays all active channels, sets edge trigger modes on highest numbered channels, sets vertical
sensitivity on channels, time base to display ~2 periods. Requires minimum voltage >20 mVpp, 1% duty
cycle and minimum frequency >50 Hz
5.7 inch diagonal color QVGA TFT LCD display with 300 cd/m
OFF, Infinite
Dots, Vectors
400 waveforms/sec
10 setups and 10 waveforms can be saved and recalled using internal non-volatile memory locations. 1 reference
waveform can be saved and recalled using an internal volatile memory location for visual comparisons.
Setups: STP saved and recalled
Waveforms: WFM saved and recalled, CSV saved
Reference waveforms: REF saved and recalled for visual comparisons
Images: 8-bit BMP, 24-bit BMP, PNG saved
2
backlight intensity
9