DNC-T2310-A10 NCC, DNC-T2310-A10 Datasheet

no-image

DNC-T2310-A10

Manufacturer Part Number
DNC-T2310-A10
Description
Dust Collector Control; 105 to 135 VAC; 10 VA; 50/60 Hz
Manufacturer
NCC
Type
Dust Collectorr
Datasheet

Specifications of DNC-T2310-A10

Communication
RS-232
Contact Form
SPST
Current, Input
4.3 mA
Dimensions
8.75"L×6.875"W×2.5"H
Frequency
50⁄60 Hz
Input Type
Voltage
Mounting Type
Panel
Number Of Inputs
3
Number Of Outputs
10
Output Type
Digital
Power Consumption
10 VA
Power, Rating
200 VA/W
Primary Type
Controller
Special Features
Serial Communications
Standards
UL, cUL
Temperature, Operating
-40 to +150 °C
Voltage, Rating
105 to 135 VAC
Voltage, Supply
100 to 240 VAC
4-14
Intelligent, AC-Input, Pulse Cleaning
of Bag House Dust Collectors
Models DNC-T2310 and DNC-T2320
FEATURES
Models T2310 and T2320 are micro-
processor-based bag house filter controllers
which combine a ten or twenty output
sequencer with a solid state differential
pressure sensor. This offers a small, low-
cost replacement to the separate solid state
sequencer and pressure gauge combination
most often used in on-demand pulse jet
cleaning systems. These controllers will
sense the pressure difference across the
filters of a bag house and initiate a cleaning
On-board differential pressure sensor
4 - 20 mA output for DP
8 character alpha-numeric display
Microprocessor based control for stable
timing from -40°C to 65°C
Enhanced timer option: monitor addi-
tional devices; record dust collector
data; network timers together remote
network monitor; remote network con-
trol
RS232 port for remote monitor and con-
trol
Automatic output setup capability
Expanded cycle mode allows additional
dust collector controllers to expand out-
put capabilities
High pressure alarm indication
Output fault detection
Alarm output contacts
Alarm input sensors
Pulse time: line synchronized to elimi-
nate 8 ms triac turn off variation per
output
10 A 400 V output triacs for maximum
protection against output shorts; 200 VA
load rating
Conformally coated for protection
against vibration, humidity, and con-
tamination
Metal chassis provided: for mounting
directly into nema 4 box
Timer functionally tested to eliminate
field failures
Input protection: 30 joule metal oxide
varistor
One year warranty: warranted to be
free from defects in materials or work-
manship for one year from date of man-
ufacture
DUST COLLECTOR CONTROLS
File #E65038
cycle when the filters start to impede the air
flow. When the pressure drops to normal the
controller will stop cycling.
Standard Operating Logic: The timers can
operate in the following modes:
Standard Timer Operation Status
Indication: The Timer can show the follow-
ing information on its 8-character alpha-
numeric display during normal operation:
Upon occurance of any alarm event, the
alarm status is reported on the display
along with the output number that was
pulsed during the time of the event.
Auto output: only configured outputs will
be pulsed. Output faults will be detected
and indicated.
Manual output: outputs will recycle after
last output used.
Output step: a single cleaning pulse can
be initiated by pressing the output step
key regardless of pressure input.
Continuous cycle: controller will cycle
indefinitely when the bypass/cycle down
input is shorted.
Cycle down: the outputs will be pulsed
through a user seleced number of com-
plete cycles when the bypass/cycle down
input is shorted. This cycle will occur
regardless of pressure input.
Expanded output mode: controller will
cycle to output #10 or #20, then will ini-
tiate an extended output mode via the
alarm input and output terminals to
NCC’s DNC-T2000 series dust collec-
tor controllers. This will facilitate sys-
tems which require greater than 10 or 20
outputs.
DP from 0” to 15” water column
High or Low DP Alarms
Solenoid Fault Conditions
Current Output being Pulsed
Auxiliary Alarm Input Closures
Alarm Outputs: The isolated Alarm
Output contacts will close for alarm
conditions such as output faults,
high pressure alarm, warm-up failure,
etc. During an alarm condition, a
corresponding message is displayed.
Alarm Input: A closure across the Alarm
Input terminals will be indicated on
the display as well as initiate the Alarm
Output.
In addition to the standard opera-
tion of the T2310 and T2320,
an enhanced operation option
is available with the use of the
DNC-T2300-I/O Remote Input/
Output module in conjunction
with the DNC-T2300-DSP Remote
Annunciator Panel. The T2310
and T2320 Timers along with the
DNC-T2300-I/O constitutes the
Enhanced Timer system which
allows the user to monitor and
record the data parameters associ-
ated with a dust collector system.
This system can range in size from
1 to 255 dust collectors, all report-
ing to a central location, the DNC-
T2300-DSP.
Enhanced Timer Operation
Status Indication: The Timer can
show the following information on
its 8 character alpha-numeric dis-
play during normal operation:
Upon occurance of any alarm
event, the alarm status is reported
on the display along with the out-
put number that was pulsed during
the time of the event.
DP from 0” to 15” water column
High or Low DP Alarms
Solenoid Fault Conditions
Current Output being Pulsed
Auxiliary Alarm Input Closures
DNC-T2300-I/O Analog Input
Status
DNC-T2300-I/O Alarm Input
Closures

Related parts for DNC-T2310-A10

DNC-T2310-A10 Summary of contents

Page 1

... This system can range in size from 1 to 255 dust collectors, all report- ing to a central location, the DNC- T2300-DSP. Enhanced Timer Operation Status Indication: The Timer can show the following information on ...

Page 2

... Operating Temperature Range: -40° to 65°C Environmental Protection: Conformal coating for humidity and vibration Contact factory for additional information OFF TIME PART NUMBER 7 to 999 sec. DNC-T2310-A10 7 to 999 sec. DNC-T2310-B10 7 to 999 sec. DNC-T2310-A220 7 to 999 sec. DNC-T2310-B220 7 to 999 sec. ...

Page 3

... Model DNC-T2310-A10 2.5 MAX. .06 THICK ALUMINUM MOUNTING PLATE Model DNC-T2320-A10 2.5 MAX. AUX ALARM INPUTS FUSE #6 SCREW TERM . (26 PL. ) .06 THICK ALUMINU M MOUNTIN G PLATE DUST COLLECTOR CONTROLS VACUUM FLUORESCENT DISPLAY (8 CHAR.) (16 SEGMENT) 6.875 .312 6.250 2.275 DIFFERENTIAL PRESSURE ( P) D INCHES OF WATER National Controls Corporation 1725 Western Dr ...

Related keywords