Manufacturer Part Number
ZFC100-04B
Description
Filter, Air Suction; 4 mm; 10 L/min. (ANR) (Min.); -100 to 0 kPa; 0 to 60 degC
Manufacturer
SMC Corporation
Datasheet

Specifications of ZFC100-04B

Diameter, Tube
4 mm
Flow Rate
10 L⁄min. (ANR) (Min.)
Material, Tube
Nylon, Soft Nylon, Polyurethane, Soft Polyurethane
Pressure, Operating
-100 to 0 kPa
Size, Element
12 mm D1 x 8 mm D2 x 20 mm L
Temperature, Operating
0 to 60 °C
1. Do not use in lines where a pressurized condition is maintained,
1. Connect tubing to the IN and OUT One-touch fittings in
1. Make connections after confirming the “ ” marks for IN and
1. When the element becomes clogged, stop operation and adjust
1. As a rule, replace the element when the pressure drops by 0.02
2. During disassembly and assembly, confirm that there are no
13-10-10
Series
Be sure to read before handling. Refer to pages 13-15-3 to 13-15-4 for Safety Instructions and Common
Precautions on the products mentioned in this catalog, and refer to page 13-1-5 for Precautions on every series.
as the body may be damaged.
accordance with the precautions for One-touch fittings.
OUT indicated on the body. Proper sealing of the element
cannot be guaranteed if connections are reversed.
the internal pressure of the filter to atmospheric pressure
before replacing the element.
MPa.
scratches or damage, etc, on the O-ring.
Warning
Warning
Caution
Warning
Caution
ZFC
Maintenance
Selection
Mounting
Precautions
1. Tubing attachment/detachment for One-touch fittings
1) Installing the tubing
2) Removal of tubing (ZFC200/201)
3) Removal of tubing (ZFC100/101)
4) For SMC’s One-touch fitting series KQ, do not install
Caution
(1) Use tubing with no flaws on its periphery and cut it off at
(2) Grasp the tubing and push it in slowly, inserting it
(3) After inserting the tubing, pull on it lightly to confirm that it
(1) Push in the release bushing sufficiently. When doing this,
(2) Pull out the tubing while holding down the release
(3) When the removed tubing is to be used again, cut off the
1. Hold the collar of the release bushing with the thumb and
2. Firmly grasp the tubing with the remaining three fingers
3. From this condition, while pushing in the release bushing
4. To reuse the tubing which has been removed, first cut off
(Perform with one hand.)
products with a metal rod into the pipe fittings of the series
ZFC100/101. The metal rod will not be held and the fitting
will shoot out.
index finger.
and the palm of the hand.
with thumb and index fingers, pull the tubing out with
three fingers and a palm of your hand.
the part which has been previously held.
a right angle. When cutting the tubing, use a tube cutter,
TK-1, 2 or 3. Do not use pinchers, nippers or scissors,
etc. If cutting is done with tools other than tube cutters,
the tubing may be cut diagonally or become flattened,
etc. This can make a secure installation impossible, and
cause problems such as the tubing pulling out after
installation or air leakage. Allow some extra length in the
tubing.
securely all the way into the fitting.
will not come out. If it is not installed securely all the way
into the fitting, this can cause problems such as air
leakage or the tubing pulling out.
push the collar evenly.
bushing so that it does not come out. If the release
bushing is not pressed down sufficiently, there will be
increased bite on the tubing and it will become more
difficult to pull it out.
portion which has been chewed before reusing it. If the
chewed portion of the tubing is used as is, this can cause
trouble such as air leakage or difficulty in removing the
tubing.
Handling of One-touch Fittings