VBA40A-T04-Z SMC Corporation, VBA40A-T04-Z Datasheet - Page 3

no-image

VBA40A-T04-Z

Manufacturer Part Number
VBA40A-T04-Z
Description
BOOSTER REGULATOR, 1/2 NPTF PORT, HANDLE OPERATED TYPE, PSI
Manufacturer
SMC Corporation
Datasheet

Specifications of VBA40A-T04-Z

Brand/series
VBA Series
Flow Rate
1900 SCFM
Pressure Adjustment
Handle Operating
Pressure Increase Ratio
Twice
Pressure, Operating
1 MPa
Proof Pressure
1.5 MPa
Size, Port
1⁄2 in.
Temperature, Ambient
2 to 50
Thread Type
NPTF
Air Tank
Perfect fit with a booster regulator
This is an air tank to which a booster regulator can be connected
compactly. It can be used alone as a tank. The pressure vessel law is
different from country to country, so as an air tank suitable to a
country needs to be confirmed.
Extensive product lineup
To meet a variety of usage environment and pressure specifications,
models are available in two materials, stainless steel 304 and carbon
steel (SS400), and in four sizes ranging from 5 liters to 38 liters.
Body size
Tank capacity (L)
Max. operating pressure (MPa)
Material
Tank capacity (L)
Max. operating pressure (MPa)
Material
Pressure increase ratio
Model
Model
1/4"
3/8"
1/2"
Set pressure
Operation
range
VBAT05A
VBAT05S
Series
5
5
2.0
0.2 to 1.0 MPa
VBA20A-03
VBA40A-04
VBAT10A
VBAT10S
VBAT
10
10
Stainless steel
Carbon steel
2.0
VBAT20A
Handle-operated type
VBAT20S
(Direct operation)
20
20
1.0
VBAT38A
VBAT38S
(0.2 to 2.0 MPa)
(0.2 to 1.6 MPa)
0.2 to 1.6 MPa
38
38
VBA10A-02
VBA43A-04
Twice
(2.0 MPa)
When used as a single unit (not connected with a booster regulator) and
pressurized at over 1 MPa at normal temperatures, the air tank falls
under the scope of the “High Pressure Gas Safety Act” in Japan.
Caution
(Remote operation)
0.2 to 1.0 MPa
Air-operated type
VBA42A-04
VBA22A-03
Handle-operated type
0.2 to 2.0 MPa
(Direct operation)
VBA11A-02
2 to 4 times
Features 2
P. 12
P. 1

Related parts for VBA40A-T04-Z