Specifications of ISE40-01-62L

Current, Consumption
55 mA (Max.)
Current, Rating
80 mA (Load)
Display Type
3-1⁄2 Digit LED
Enclosure Type
IP65
Length, Wire
600 mm
Output Type
PNP
Pressure, Operating
0.000 to 1.000 Mpa
Repeatability
± 0.2% F.S. (± 1Digit)
Resistance, Insulation
50 Megohms (Min.)
Size, Port
R 1⁄8, M5 x 0.8
Standards
UL Listed, CSA Certified, CE Approved
Temperature, Ambient
0 to +50 °C
Voltage, Input
12 to 24 VDC (± 10%)
For vacuum/compound pressure
∗ Option
01: R 1/8 (With M5 female threads)
T1: NPT 1/8 (With M5 female threads)
Wall mount
∗ C4: With ø4 One-touch fitting
∗ C6: With ø6 One-touch fitting
For positive pressure
Nil
F
Nil
10.0 to –101.3 kPa
–100.0 to 100.0 kPa
–0.100 to 1.000 MPa
R 1/8, NPT 1/8
M5 x 0.8 female threads
ø4, ø6
One-touch fitting
Note
When equipped with auto shift function, the following ranges can be set.
∗ Option
22
30 ∗
62 ∗
70 ∗
–100.0 to 100.0 kPa
Set pressure range
Set pressure range
For vacuum pressure
For compound pressure
Set pressure range
10.0 to –101.3 kPa
–0.1 to 1.000 MPa
∗ M5: M5 x 0.8 (Female threads)
For positive pressure
W1: Rc 1/8
Reverse pressure
two directions
Wall mount
NPN open collector 2 outputs + analog output
NPN open collector 2 outputs + auto shift input
PNP open collector 2 outputs + analog output
PNP open collector 2 outputs + auto shift input
ZSE40
ISE40
Piping specifications
Digital Pressure Switch
Input/Output specifications
M5 x 0.8
How to Order
Rc 1/8
Rc 1/8
–1.000 to 1.000 MPa
–100.0 to 100.0 kPa
–101.3 to 101.3 kPa
High Precision,
Setting range
01
01
22
22
Series
Lead wire length
Nil
L
0.6 m
3 m
Note 1) This will no longer be sold for use in
Note 2) Fixed unit
Unit specifications
Nil
M
ZSE40/ISE40
∗ When optional parts only are
required, order with the part
numbers inside ( ).
Option
Japan after the new Weight and
Measure Act is implemented
(October,1999).
For vacuum/compound pressure: kPa
For positive pressure: MPa
Nil
With unit switching function
A
B
E
F
None
Bracket A
Bracket B
Panel mount
Panel mount
+ Front protective cover
SI unit only
Note 2)
(ZS-24-C)
(ZS-22-A)
(ZS-24-A)
(ZS-24-B)
16-2-17
Note1)

Related parts for ISE40-01-62L

ISE40-01-62L Summary of contents

Page 1

... Digital Pressure Switch How to Order 1 0.8 Input/Output specifications Setting range Lead wire length –100.0 to 100.0 kPa –101.3 to 101.3 kPa –1.000 to 1.000 MPa ZSE40/ISE40 Option Nil None Bracket A (ZS-24-A) A Bracket B (ZS-24-B) B Panel mount (ZS-22-A) E Panel mount (ZS-24-C) + Front protective cover F ∗ ...

Page 2

... Weight 01/T1 types approx type approx C4/C6/M5 types approx (Each including 0.6 m lead wires) Note 1) Equipped with unit switching function (Types without the unit switching function use SI units (kPa or MPa) only.) 22 Note 2) For ZSE40 (F)/ISE40-„ Note 3) For ZSE40 (F)/ISE40-„- 70 Note 4) For ZSE40F (compound pressure) with “ ...

Related keywords