U1602B-001 Agilent Technologies Test Equipment, U1602B-001 Datasheet - Page 9

no-image

U1602B-001

Manufacturer Part Number
U1602B-001
Description
Digital Oscilloscope, Handheld, Orange, 20 MHz with USB Port
Manufacturer
Agilent Technologies Test Equipment
Type
Digitalr
Datasheet

Specifications of U1602B-001

Bandwidth
20 MHz
Brand/series
U1600 Series
Configuration
Handheld
Display Type
Color LCD
Memory
125 Kpts
Number Of Channels
2
Sample Rate
0.2 GS/s
OPTIONAL ACCESSORIES
Item
U1168A Standard test lead kit
(with 19-mm and 4-mm probe tips)
U1161A Extended test lead kit
U1162A Alligator clips
U1163A SMT grabbers
U1164A Fine-tip test probes
U1169A Test probe leads (with
19-mm tips and 4-mm tips)
U1181A Immersion temperature
probe
U1182A Industrial surface
temperature probe
U1183A Air temperature probe
Description
• Test leads: CAT III 1000 V, CAT IV 600 V, 15 A
• Test probe (19-mm tips): CAT III 1000 V, CAT IV 600 V, 15 A
• Test probe (4-mm tips): CAT III 1000 V, CAT IV 600 V, 15 A
• Alligator Clips: CAT III 1000 V, 10 A
• Fine tip test probes: CAT II 300 V, 3 A
• SMT grabber: CAT II 300 V, 3 A
• Mini grabber (black only): CAT II 300V, 3 A
• Includes two test leads (red and black),
• Test leads: CAT III 1000 V, CAT IV 600 V, 15 A
• Test Probes: CAT III 1000 V, 15 A
• Medium Sized Alligator Clips: CAT III 600 V, 10 A
• 4 mm Banana Plugs: CAT II 600 V, 10 A
• One pair of insulated alligator clips (red and black)
• Recommended for use with Agilent standard test
• Rated CAT III 1000 V, 10 A
• One pair of SMT grabbers (red and black)
• Recommended for use with Agilent standard test leads
• Rated CAT II 300 V, 3 A
• One pair of insulated alligator clips (red and black)
• Recommended for use with Agilent
• Rated CAT II 300 V, 3 A
• Test leads: CAT III 1000 V, CAT IV 600 V, 15 A
• Test probe (19-mm tips): CAT III 1000 V, CAT IV 600 V, 15 A
• Test probe (4-mm tips): CAT III 1000 V, CAT IV 600 V, 15 A
• Type-K thermocouple for use in oil and other liquids
• Measurement range: –50 °C to 700 °C
• Temperature module (U1586A) is required to connect
• U1184A Temperature probe adapter included for use with
• Type-K thermocouple for use in still surface temperature
• Measurement range: –50 °C to 400 °C
• Temperature module (U1586A) is required to connect
• U1184A Temperature probe adapter included for use with
• Type-K thermocouple for use in air and non-caustic gas
• Measurement range: –50 °C to 800 °C
• Temperature module (U1586A) is required to connect
• U1184A Temperature probe adapter included for use with
9
(highly recommended for CAT IV environment)
two test probes, medium sized alligator clips and
4 mm banana plugs
standard test leads
(highly recommended for CAT IV environment)
temperature measurements
to DMM inputs of the handheld scope
DMMs
measurements
to DMM inputs of the handheld scope
DMMs
temperature measurements
to DMM inputs of the handheld scope
DMMs
leads