CLN-500 Pacific Scientific OECO, CLN-500 Datasheet

no-image

CLN-500

Manufacturer Part Number
CLN-500
Description
Sensor, Current; 500APri:0 to 100kHz; Panel; 3 Faston Term.; 100mA; 1:5000 Turns
Manufacturer
Pacific Scientific OECO
Type
Hall Effectr
Datasheet

Specifications of CLN-500

Accuracy
± 0.5% @ 25 °C
Brand/series
CLN
Current, Primary
500 A (RMS)
Current, Secondary
100 mA
Current, Switching
100 mA
Diameter, Inside
1.023 in.
Frequency Response
0 to 100 kHz
Function
Current
Height
4.22 in.
Length
3.543 in.
Mounting Type
Panel
Output
Current
Primary Type
Current
Range, Measurement
1200 A
Technology
Hall Effect
Termination
Faston
Turns Ratio
1:5000
Voltage, Supply
24 VDC
Width
0.071 in.
Lead Free Status / Rohs Status
RoHS Compliant part
For Use With
Variable speed drive for motors, welding equipment, power supply equipment, measure and control system
Applications
• Variable speed drives for motors
• Welding Equipment
• Power supply Equipment
Features
• Noncontact measurement of high current
• Measures DC, AC and impulse currents
• Current sensing up to 400A peak
• Very fast response and high accuracy
Description
currents and provides electrical isolation between the current carrying
conductor and the output of the sensor.
Model CLN-500 is a closed loop current sensor that accurately measures DC and AC
Electrical Specifications
Nominal current (I
Measuring range
Sense resistor .............................................
Nominal analog output current .....................
Turns ratio ..................................................
Overall accuracy at 25 °C.............................
Supply voltage (VDC) ....................................
Dielectric strength.......................................
Accuracy-Dynamic Per formance
Zero current offset at 25°C .........................
Offset current temperature drift ....................
Linearity .....................................................
Response time ............................................
di/dt accurately followed .............................
Bandwidth ..................................................
General Information
Operating temperature ................................
Storage temperature ....................................
Current drain (plus output current) ................
Coil resistance ............................................
Package .....................................................
Weight .......................................................
Mounting ....................................................
Aperture size...............................................
Output connection .......................................
Output reference ........................................
(between 0°C and +70°C )
(between the current carrying conductor
and the output of the sensor)
Notes:
1.The temperature of the current carrying conductor should not exceed 100
with ± 18 V at ±1000 A peak .........
with ±12V at ±1000 A peak .........
with ± 24 V at ±500 A peak .........
with ±15V at ±500 A peak .........
.........................................
N
)
....................................
at ±1000 A peak .........
at ±1500 A peak .........
at ±1500 A peak .........
at ±1200 A peak .........
at ±1200 A peak .........
• Measure and control system
• Over current protection
• Protection of power semiconductors
• High overload capacity
• Light duty industrial housing
• Solid core with aperture
To obtain a positive output on the terminal marked “O/P”, aperture
current must flow in the direction of the arrow (conventional flow)
±0.2 mA typ., ± 0.3 mA max.
o
C.
1.02 inch dia. (26 mm)
flame retardant plastic case
Panel mount via 4 slots
R. min.
10 ohm
10 ohm
(6.30mm x 0.80mm)
0 ohm
0 ohm
22 mA (at ± 24V)
3 Faston terminals
6 kV rms/50 Hz/1 min.
50 ohm (at 70°C)
-40°C to +85°C
-40°C to +90°C
better than 50 A/µs
0 to 100 kHz (-1dB)
n/a
n/a
n/a
n/a
n/a
better than ±0.1%
0.248" x 0.031"
±15 to ± 24 (±5%)
0 to ±1200 A
CLN-500
less than 1 µs
500 A rms
340 grams
±0.2 mA max.
±0.5% of I
100 mA
1:5000
130 ohm
25 ohm
R. max.
50 ohm
5 ohm
n/a
n/a
n/a
n/a
n/a
N

Related parts for CLN-500

CLN-500 Summary of contents

Page 1

... Description Model CLN-500 is a closed loop current sensor that accurately measures DC and AC currents and provides electrical isolation between the current carrying conductor and the output of the sensor. Features • Noncontact measurement of high current • Measures DC, AC and impulse currents • Current sensing up to 400A peak • ...

Page 2

... Mechanical Dimensions All dimensions are in inches (millimeters) Model CLN-500 CLN-500 2.756 (70.00) .512 (13.00) 1.378 (35.00) .260 (6.6) MOUNTING SLOT (4) 2.756 (70.00) 2.992 (76.00) FASTON TERMINALS (3) .248" x .031" (6.3mm x .80mm) .394 (10.01) + .394 (10.01) O/P 1.024 (26.00) 3.543 (90.00) 2.087 (53.01) 3.307 (84 ...

Related keywords