G27-P10-R1-X30 SMC Corporation, G27-P10-R1-X30 Datasheet - Page 14

no-image

G27-P10-R1-X30

Manufacturer Part Number
G27-P10-R1-X30
Description
GAUGE, PRESSURE, PNEUMATIC, FOR AR10
Manufacturer
SMC Corporation
Datasheet

Specifications of G27-P10-R1-X30

Range
0-160 psi
For Use With
AR10
(1) Before setting the (green) limit indicator, turn the
(2) Use a flat head screwdriver (with a 2.9 mm blade
1. Do not apply high load voltage (current) or surge current as
2. Make sure that no direct impact or vibrations are applied to the
3. If operating under pressure pulsations or in high frequency op-
1. During transport and installation, do not apply shock to the
2. Regarding the installation posture, place it perpendicular to the
3. Do not install it in an area that is exposed to high temperature
4. To screw in the pressure gauge, make sure to turn the gauge
(3) After completing the setting, replace the cover.
Procedure for Setting the Limit Gauge Indicator
Be sure to read before handling. Refer to pages
14-21-3 to 14-21-4 for Safety Instructions and
Common Precautions.
this can cause the switch to malfunction.
body.
erations, please contact SMC.
product, such as by dropping doing so will affect its precision.
ground, with the zero point on the reading of a pressure gauge
facing down.
or humidity, because doing so will lead to improper operation.
by placing a wrench over the square wrench flats.If the pres-
sure gauge is screwed in by holding it on some other area, air
leakage or damage may result.
width) to set the (green) limit indicator. Be careful
not to bend the other needle or damage the dial
plate.
cover counterclockwise (approximately 6 to 7
mm) until it stops. Then, remove by pulling it to-
wards you.
Fit the cover by aligning the cutout in the cover to
the groove on the top of the black case. Turn the
cover clockwise (approximately 6 to 7 mm) until it
stops. Make sure that the matching mark on the
cover is aligned with the groove on the top of the
case.
Caution
Caution
Mark
Limit indicator
Cover
Top hollow
Flat head screwdriver
Precautions
Turn counterclockwise
Pull
Mounting
Selection
Slit
(1) Before setting the limit indicator and the (green)
(3) Before setting the setting needle, use a flat head
(4) After completing the setting, replace the cover.
(2) Use a flat head screwdriver (with a 2.9 mm blade
1. Remove the small screw (1 position) from the pressure gauge.
2. Place the cover ring on the pressure gauge.
3. Using the small screw that is provided with the cover ring, in-
Procedure for Setting the Limit Gauge Indicator and the Setting Needle
Procedure for Assembling the Cover Ring Assembly
Pressure gauge with switch
Pressure gauge for general purpose
stall the cover ring. The installation torque is 0.3 to 0.5 N·m.
setting needle, turn the cover counterclockwise
(approximately 6 to 7 mm) until it stops. Then, re-
move by pulling it towards you.
width) to set the (green) limit indicator. Be careful
not to bend the other needle or damage the dial
plate.
screwdriver (with a 2.9 mm blade width) to turn
the setting screw and set the setting needle to
the set pressure.
Fit the cover by aligning the cutout in the cover to
the groove on the top of the black case. Turn the
cover clockwise (approximately 6 to 7 mm) until it
stops. Make sure that the matching mark on the
cover is aligned with the groove on the top of the
case.
Mark
Limit indicator
Flat head screwdriver
Cover
Flat head screwdriver
Top hollow
In the case of turning the set
screw
• Clockwise
• Counterclockwise
Turn counterclockwise
Increase of setting press.
Decrease of setting press.
Pull
Slit
Pressure
switch
Remove screw
Remove screw
Pressure Gauge Guide
Cover ring
Attach small screw
14-11-15
F.R.L.
AV
AU
AF
AR
IR
VEX
AMR
ITV
IC
VBA
VE„
VY1
G
PPA
AL

Related parts for G27-P10-R1-X30