CLSM-50 Pacific Scientific OECO, CLSM-50 Datasheet

no-image

CLSM-50

Manufacturer Part Number
CLSM-50
Description
Sensor, Current; +/-50A Pri:DC to 100kHz; 50mA; 1000/1 Turns; +/-0.5%; UL Listed; 1.6I
Manufacturer
Pacific Scientific OECO
Type
Inductiver
Datasheet

Specifications of CLSM-50

Accuracy
± 0.5% @ 25 °C
Current, Primary
± 50 A (RMS)
Current, Secondary
50 mA
Frequency Response
DC to 100 kHz
Function
Current
Height
4.22 in.
Length
1.6 in.
Output
Current
Primary Type
Current
Range, Measurement
50 A
Standards
UL Listed
Technology
Inductive
Turns Ratio
1000⁄1
Width
0.071 in.
Lead Free Status / Rohs Status
RoHS Compliant part Electrostatic Device
For Use With
Measures DC, AC and impulse currents
Features
• Noncontact measurement of high current
• Measures DC, AC and impulse currents
• Current sensing up to 400A peak
• Very fast response and high accuracy
• High overload capacity
1.
2. The dynamic performance is the best when the busbar fills the aperture.
Model CLSM-50
Description
The Model CLSM-50 is a closed loop Hall effect current sensor that
accurately measures DC and AC currents and provides electrical isolation
between the current carrying conductor and the output of the sensor.
Applications
• Variable speed drives for motors
• Welding Equipment
• Power supply Equipment
• Measure and control system
• Over current protection
• Protection of power semiconductors
Notes:
3. Due to continuous process improvement, all specifications are subject to change without notice.
Storage temperature
Electrical Specifications
Nominal current (I
Current range
Nominal output current (I
Turns Ratio
Measuring Resistance (R
Overall accuracy at 25º C
Supply voltage
Current consumption
Response time
General Information
Operating
Output reference..................................................
Weight
Mounting .................................................................. Designed to mount directly on PCB via through hole connection pins
Aperture size ........................................................................................................ 0.256" x 0.512" (6.5 x 13 mm)
Frequency range
Package
Isolation voltage
Accuracy-Dynamic Performance
Zero current offset at
Offset current temperature drift (0ºC to +70ºC)
Linearity
di / dt
Busbar temperature should not exceed 100ºC.
..............................................................................................................
...............................................................................................................
...........................................................................................................
............................................................................................
temperature..........................................................................................
.............................................................................................................
.....................................................................................................
(Vdc)..................................................................................................
..................................................................................................
...............................................................................................
N
.................................................................................................
)
...................................................................................................
...................................................................................
...........................................................................................
25ºC......................................................................................
M
M
)
)
...........................................................................................
....................................................................................
..........................................................................................
........................................................ <
must flow in the direction of the arrow (conventional flow)
To obtain a positive output on
Closed Loop Hall Effect
*at
±18V power supply, Rm <1 W, 25ºC
flame retardant plastic case, UL94V-0
15 mA + output current
terminal M, input current
5kV/50Hz/1 min.
better than 1µs
better than ±0.1%
better than 50A/µs
CLSM-50
0 to ±400 A peak*
22 grams
-40ºC to +100ºC
DC to 100KHz (-3dB)
-25ºC to +85ºC
refer to table 1
1000 / 1
< ±0.2mA
±12 to ±18
±50 A rms
±0.5% of I
±0.25mA
50 mA
N
45

Related parts for CLSM-50

CLSM-50 Summary of contents

Page 1

... Model CLSM-50 Description The Model CLSM- closed loop Hall effect current sensor that accurately measures DC and AC currents and provides electrical isolation between the current carrying conductor and the output of the sensor. Features • Noncontact measurement of high current • Measures DC, AC and impulse currents • ...

Page 2

... All dimensions are in inches (millimeters) CLSM-50 Note: Due to continuous process improvement, all specifications are subject to change without notice. 46 Dimensions Mechanical Dimensions 1.60" (40.4mm) .512" (13mm) (6.5mm) 0.24" .197" (0.6mm) (5mm) 1.12" (28.2mm) Table 1 (Rm Max) At maximum input 50 100 amps (peak) A Supply voltage ± ...