E5ANR3MT500NAC100240 Omron Automation, E5ANR3MT500NAC100240 Datasheet

no-image

E5ANR3MT500NAC100240

Manufacturer Part Number
E5ANR3MT500NAC100240
Description
Controller, Digital Temp, 96x96mm, Relay Out, Thermoc In, 100-240VAC, 3Aux Out
Manufacturer
Omron Automation
Type
Temperaturer
Datasheet

Specifications of E5ANR3MT500NAC100240

Brand/series
E5AN Series
Communication
USB
Contact Form
SPST-NO
Dimensions
96mmW×96mmH×78mmD
Enclosure Rating
IP00, IP20, IP66
Input Type
RTD/Thermocouple
Ip Rating
IP00, IP20, IP66
Mounting Type
DIN Rail
Number Of Outputs
4
Output Type
Relay
Primary Type
Controller
Special Features
USB Serial
Standards
UL, cULus, CSA
Termination
Terminal Block
Voltage, Supply
100 to 240 VAC
Supply Voltage
100-240 VAC or 24 VAC/VDC
Current Output
4-20 mA DC (E5CN-E5AN-E5EN)
Thermocouple Inputs
K, J, T, L, E, U, N, R, S, B
Platinum Rtd
Pt100 and JPt100
Infrared Sensor
10-70°C, 60-120°C, 115-165°C, 160-260°C
Voltage
0 to 50 mV
Lead Free Status / Rohs Status
RoHS Compliant part
New 96 x 96-mm and 48 x 96-mm Basic Temperature Controllers with
Enhanced Functions and Performance.
Improved Indication Accuracy and
Preventive Maintenance Function.
• Indication Accuracy
• A PV/SV-status display function can be set to automatically
• Preventive maintenance for relays in the Temperature Controller
• Three-level display that simultaneously displays the PV, SV, and
• One-touch operation with PF Key that can be assigned to auto/manual, RUN/
Main I/O Functions
Basic-type Digital Temperature Controller
E5AN/E5EN
Thermocouple input: ±0.3% of PV (previous models: ±0.5%)
Pt input: ±0.2% of PV (previous models: ±0.5%)
Analog input: ±0.2% FS (previous models: ±0.5%)
alternate between displaying the status of the Temperature
Controller (auto/manual, RUN/STOP, and alarms) and the PV or
SV.
using a Control Output ON/OFF Counter.
MV.
STOP, or other functions.
This data sheet is provided as a guideline for selecting products. Be sure to refer to the following user manuals for application precautions
and other information required for operation before attempting to use the product.
E5CN/E5AN/E5EN Digital Temperature Controllers User's Manual Basic Type (Cat. No. H156)
E5CN/E5AN/E5EN Digital Temperature Controllers Communications Manual Basic Type (Cat. No. H158)
Sensor Inputs
• Universal thermocouple/Pt inputs
• Analog current/voltage inputs
Indication Accuracy
• Thermocouple input: ±0.3% of PV
• Pt input: ±0.2% of PV
• Analog input: ±0.2% FS
Sampling Period
• 250 ms
(Models with temperature inputs)
(Models with analog inputs)
PF Key
(Programmable function key)
Event Inputs
• None
• Two
Control Output 1
• Relay output
• Voltage output (for driving SSR)
• Current output
E5AN
Control Output 2
• Voltage output
• Long-life relay
output (hybrid)
(for driving SSR)
(96 x 96 mm and 48 x 96 mm)
E5EN
Auxiliary Outputs
• Three
96 × 96 mm
4-digit Display
E5AN
3-level Display ✽
Simultaneously displays set items,
such as the PV, SV, and MV.
✽ A 2-level display when shipped from the factory. A
3-level display is activated if parameters are
initialized. For details on the third display level, refer
to the User’s Manual, Basic Type (Cat. No. H156).
Refer to Safety Precautions on page 66.
• Auto/manual switching
• Temperature Controller
• Simple program function
• Control output ON/OFF
• PV change rate alarm
• Models also available with
status display
count alarm
RS-485 or RS-232C
communications
48 × 96 mm
E5EN
17

Related parts for E5ANR3MT500NAC100240

E5ANR3MT500NAC100240 Summary of contents

Page 1

Basic-type Digital Temperature Controller E5AN/E5EN New 96 x 96-mm and 48 x 96-mm Basic Temperature Controllers with Enhanced Functions and Performance. Improved Indication Accuracy and Preventive Maintenance Function. • Indication Accuracy Thermocouple input: ±0. (previous models: ±0.5%) Pt ...

Page 2

E5AN/E5EN Lineup E5AN/E5EN Terminal block Basic Type Note: Models with one control output or two control outputs can be used for heating/cooling control. Model Number Structure Model Number Legend Controllers E5AN/E5EN-@3@M@@-@-500 Control ...

Page 3

Ordering Information E5AN Controllers with Terminal Blocks Power Case Size supply Input type color voltage Thermocouple or Resistance thermometer 100 to 240 VAC Black 1/4 DIN 96 × 96 × 78 Analog (W × H × D) (current/voltage) Thermocouple 24 ...

Page 4

E5AN/E5EN E5EN Controllers with Terminal Blocks Power Case Size supply Input type color voltage Thermocouple or Resistance thermometer 100 to 240 VAC Black 1/8 DIN 48 × 96 × × H × D) Analog (current/volt- age) Thermocouple 24 ...

Page 5

Option Units Name Communications Unit Event Input Unit Accessories (Order Separately) USB-Serial Conversion Cable Model E58-CIFQ1 Terminal Cover Connectable models Model E5AN E53-COV16 E5EN Note: The Terminal Cover comes with the E5CN-@@@-500 models. Waterproof Packing Connectable models Model E5AN Y92S-P4 ...

Page 6

E5AN/E5EN Specifications Ratings model number: 100 to 240 VAC, 50/60 Hz Power supply voltage D in model number: 24 VAC, 50/60 Hz; 24 VDC Operating voltage range 85% to 110% of rated supply voltage Power 100 to ...

Page 7

Input Ranges Thermocouple/Platinum Resistance Thermometer (Universal inputs) Input Platinum resistance type thermometer Name Pt100 JPt100 K J 2300 1800 1700 1600 1500 1400 1300 1300 1200 1100 1000 850 850 900 800 700 600 500.0 500.0 500.0 500 400 300 ...

Page 8

E5AN/E5EN Alarm Outputs Each alarm can be independently set to one of the following 13 alarm types. The default is 2: Upper limit. Auxiliary outputs are allocated for alarms. ON delays and OFF delays (0 to 999 s) can also ...

Page 9

Characteristics Thermocouple: (±0.3% of indicated value or ±1°C, whichever is greater) ±1 digit max. ✽1 Platinum resistance thermometer: (±0.2% of indicated value or ±0.8°C, whichever is greater) ±1 digit max. Indication accuracy Analog input: ±0.2% FS ±1 digit max. CT ...

Page 10

E5AN/E5EN USB-Serial Conversion Cable Applicable OS Windows 2000, XP, or Vista Thermo Mini, CX-Thermo version Applicable software 4.0 or higher E5AN/E5EN/E5CN/E5CN-U/E5AN- Applicable models H/E5EN-H/E5CN-H USB interface standard Conforms to USB Specification 1.1. DTE speed 38400 bps Computer: USB (type A ...

Page 11

External Connections • A voltage output (control output 1, for driving SSR) is not electrically insulated from the internal circuits. When using a grounding thermocouple, do not connect any of the control output terminals to ground. If the control output ...

Page 12

E5AN/E5EN Nomenclature E5AN Temperature unit SUB1 SUB2 SUB3 Operation indicators HA OUT1 STOP OUT2 CMW MANU Programmable PF Function Key/ A/M Auto/Manual Key E5AN Level Key Mode Key ✽ A 2-level display when shipped from the factory. A 3-level display ...

Page 13

E5EN 48 112 96 Waterproof Packing (Accessory) Accessories (Order Separately) USB-Serial Conversion Cable E58-CIFQ1 USB connector (type A plug) Terminal Covers E53-COV16 (Six Covers provided 120 min. Terminal Cover Mounting Bracket (E53-COV16) (Accessory) (Accessory) Crimp terminal ...

Page 14

E5AN/E5EN Waterproof Packing Y92S-P4 (for DIN 96 × 96) Y92S-P5 (for DIN 48 × 96) Current Transformers E54-CT1 E54-CT3 30 40 × E54-CT3 Accessory • Armature Connection Example Plug Approx. 3 dia. 18 • ...

Related keywords