44536-0170 Sti (Scientific Technologies, Inc.), 44536-0170 Datasheet - Page 3

no-image

44536-0170

Manufacturer Part Number
44536-0170
Description
CONTROL UNIT, CM-SE, EXPANSION MODULE 24VAC/DC(UP TO 5 CM SWITCHES)
Manufacturer
Sti (Scientific Technologies, Inc.)
Datasheet

Specifications of 44536-0170

Lead Free Status / Rohs Status
RoHS Compliant part
G
In the illustration above, the guard door is open and the machine is
stopped. Machine will start when the guard door is closed, and the reset
button is pressed.
CM Series
ing guard doors or swinging guard
doors.
MECHANICAL
G66
L (+ve)
N (-ve)
EMERGENCY
SWITCHES
Applications
Typical applications are on slid-
SAFETY
STOP
or
OmrOn Scientific technOlOgieS, inc.
USA
Tel. 1/888/510-4357
A1
CM-S41
A2
POWER
S13
S14
RUN
S23
S24
1
2
3
4
X1
X2
DE-SELECT
BL
BL
GATE 1
GATE 3
GS1
GATE 2
GATE 3
GATE 4
GS3
canada
DR
DR
BL
BL
GATE 2
GATE 4
GS2
GS4
DR
DR
Tel. 1/866/986-6766
K1
31
32
F1
13
14
23
24
F2
K2
MANUAL
RE-SET
K1
K2
K1
K2
24 V +ve
0 V -ve
For the Latest Information
On the Internet: www.sti.com or www.omron.ca
In the illustration above, all of the guard doors are open and the machine
is stopped. Machine will start when all the guard doors are closed, and the
reset button is pressed.
A1
A2
CM-SE
DR
DR
GATE 1
GATE 4
GS1
GS4
POWER
BL
BL
DR
DR
GATE 2
GATE 5
GS2
GS5
BL
BL
DR
DR
GATE 3
IND 1
IND 2
IND 3
IND 4
IND 5
GS3
BUS
BL
BL
2-WIRE BUS CONNECTION
N
A
Go to the Engineering Guide
For in-depth information on
safety standards and use.
For More Guarding Products
See Section N for safeguarding
cutting and turning machines
CM-S41 or CM-S21
an active gate input.
Connect the CM-SE
CONTROL UNIT
Bus connection to
A1
A2
BL DR