LU20-5001-IS Flowline, LU20-5001-IS Datasheet

no-image

LU20-5001-IS

Manufacturer Part Number
LU20-5001-IS
Description
Sensor, Ultrasonic, 2-Wire Trans., 18 ft Range, 2 in NPT, Intrinsic.Safe, EchoTouch
Manufacturer
Flowline
Type
Level Transmitterr
Datasheet

Specifications of LU20-5001-IS

Body Style
General Purpose
Brand/series
Switch-Tek
Function
Non-contact Level Measurement
Ip Rating
IP65
Mounting Type
2 In. NPT
Output
4-20 mA
Range, Measurement
.5 to 18 Ft.
Sensing Mode
Ultrasonic
Special Features
LCD Display
Termination
Cable
Voltage, Supply
12 to 36 VDC
For Use With
Level Measurement
Features
Echotouch
Echotouch
Process mount (1) (2) (3)
Echotouch
0
6
LCD digital display indicates level
in inches or centimeters
PP enclosure rated NEMA 4X with
rugged Kynar® transducer
EasyCal simple push button cali-
bration for all user set points
Adjustable dead band and range
filters eliminate false echo returns
2" NPT (US)
2" G (Metric)
Shown
LM50
67
IP
Ordering
IP
65
LU20-50
Description
Offered in CSA and Cenelec approved intrinsically safe or general pur-
pose configurations, the two-wire ultrasonic transmitter provides non-
contact level measurement up to 18’ or 5.4m, and is ideally suited for
challenging corrosive, slurry or waste liquids. The transmitter is typical-
ly selected for atmospheric bulk storage, day tank and waste sump
applications located within a classified hazardous area. Media exam-
ples include diesel fuel and hydrochloric acid. The transmitter is cali-
brated in less than a minute using the LCD display, 4-button interface
and intuitive calibration menu. All user set points are held in non-
volatile memory. In the event of acoustic signal loss, the transmitter will
hold the current output at the user designated safe state.
Specifications
Range:
Accuracy:
Resolution:
Beam width:
Dead band:
Display type:
Display units:
Memory:
Supply voltage:
Loop resist.:
Signal output:
Signal invert:
Calibration:
Fail-safety:
Process temp.:
Temp. comp.:
Electronics temp.:
0.5' to 18'
(15 cm to 5.4m)
0.125" (3 mm)
8˚ conical
0.5' (15 cm)
LCD, 4-digit
Inch or cm
Non-volatile
12-32 VDC
600 Ohms @ 24 VDC
4-20 mA, two-wire
4-20 or 20-4 mA
Digital, push button
Reverts to safe state
during echo-loss
F: -40˚ to 140˚
C: -40˚ to 60˚
Automatic
F: -4˚ to 140˚
C: -20˚ to 60˚
TM
TM
0.25% of span in air
Ultrasonic Level Transmitter
1-IS
Shown
LB10
Ordering Notes
1) The straight G thread version seals with
2) For installation on open tanks, order the
3) To order the general purpose transmitter, do
4) To complete your IS transmitter, add the
an included Viton® mounting gasket.
LM50-1001 (2" NPT) or LM50-1061 (2" G)
side mount bracket. Locate the bracket
far enough inboard from the side wall to
avoid sensor beam width conflicts.
not specify the last two digits (ie: LU20-5001).
LB10-1001 intrinsic safety barrier.
Pressure:
Enclosure rating:
Installed height:
Encl. material:
Trans. material:
Process mount:
Mount. gasket:
Conduit entrance:
Classification:
Approvals:
Parameters:
Certificates:
CE compliance:
30 psi (2 bar) @ 25˚
C., derated @ 1.667
psi (.113 bar) per ˚C.
above 25˚ C.
NEMA 4X (IP65)
5.1" (13 cm) above
tank process mount
PP, UL94VO
PVDF Kynar®
2" NPT (2" G)
Viton® (G version only)
Single, 1/2" NPT
Intrinsically safe
CSA: Class I, Groups A,
B, C & D; Class II, Groups
E, F and G; Class III; T3C
CSA: Vmax < 32.0 V;
Imax < 130 mA; Ca =
0 F; La = 0 H
CSA: LR 79326
EN 50082-2 immunity
EN 55011 emission
Echotouch 0504 DS3_1

Related parts for LU20-5001-IS

LU20-5001-IS Summary of contents

Page 1

... Locate the bracket far enough inboard from the side wall to avoid sensor beam width conflicts order the general purpose transmitter, do not specify the last two digits (ie: LU20-5001 complete your IS transmitter, add the LB10-1001 intrinsic safety barrier. LB10 Shown ...

Page 2

Echotouch Echotouch Dimensions 2.8" (71 mm) Specifications are subject to change without notice. Beam Cone Data Depth (Feet Ultrasonic Level Transmitter To LC52 Relay Controller (+) ...