LU83-5101 Flowline, LU83-5101 Datasheet

no-image

LU83-5101

Manufacturer Part Number
LU83-5101
Description
Sensor, Ultrasonic, 2-Wire Trans., 26.2 ft Range, Display, 2 in NPT, NEMA 4X
Manufacturer
Flowline
Type
Level Transmitterr
Datasheet

Specifications of LU83-5101

Body Style
Compact
Brand/series
EchoSpan
Function
Non-contact Level Measurement
Ip Rating
IP65
Mounting Type
2 In. NPT
Output
4-20 mA
Range, Measurement
26.2 Ft.
Sensing Mode
Ultrasonic
Special Features
LCD Display
Termination
Cable
Voltage, Supply
12 to 28 VDC
For Use With
Level Measurement
EchoSpan Two-Wire Ultrasonic Level Transmitter
LU8_ Series
Specifications
EchoSpan
EchoSpan
Sensor range
Process mount (1) (2)
Range:
Accuracy:
Resolution:
Beam width:
Dead band:
Display type:
Display units:
Display mode:
Memory:
Supply voltage:
Loop resist.:
Signal output:
Signal invert:
Calibration:
Fail-safety:
Process temp.:
Temp. comp.:
Electronics temp.:
Pressure:
Enclosure rating:
Enclosure vent:
Encl. material:
Trans. material:
Process mount:
Mount. gasket:
Conduit entrance:
Classification:
CE compliance:
EchoSpan
81
83
84
0
6
5m (16.4')
8m (26.2')
10m (32.8')
NPT (US)
G (Metric)
We Do Your Level Best
LU81: 8" to 16.4'
LU83: 8" to 26.2'
LU84: 12" to 32.8'
± 0.2% of span in air
LU81/83: 0.039" (1 mm)
LU84: 0.078" (2 mm)
3" (7.6 cm) dia.
LU81: 8" (20 cm)
LU83: 8" (20 cm)
LU84: 12" (30 cm)
LCD, 6-digit
Inch, cm or percent
Air gap or liquid height
Non-volatile
12-28 VDC
500 Ohms @ 24 VDC
4-20 mA, two-wire
4-20 mA or 20-4 mA
Push button
Selectable 4mA, 20mA,
21 mA, 22 mA or hold
F: -7˚ to 140˚
C: -20˚ to 60˚
Automatic
F: -40˚ to 160˚
C: -40˚ to 71˚
30 psi (2 bar) @ 25˚
C., derated @ 1.667
psi (.113 bar) per ˚C.
above 25˚ C.
NEMA 4X (IP65)
Water tight membrane
PC/ABS FR
PVDF
2" NPT (2" G)
Viton®
Dual, 1/2" NPT
General purpose
EN 61326 EMC
Ordering
(20 cm to 5m)
(20 cm to 8m)
(30 cm to 10m)
LU
The general purpose two-wire ultra-
sonic transmitter provides non-contact
level measurement up to 32’ or 10m,
and is ideally suited for challenging
ultrapure, corrosive or waste liquids.
Push button calibrated, the transmitter
is broadly selected for atmospheric
bulk storage, day tank and waste sump
applications. Media examples include
wastewater and sodium hydroxide.
Description
TM
-51
1
Ultrasonic Level Transmitter
Faceplate
LU81/83/84
Shown
Shown
Ordering Notes
1) For installation on open tanks, order the
2) For a liquid tight cable connection, order
LM50-1001 (2" NPT) or LM50-1061 (2" G)
side mount bracket.
the LM90-1001 connector.
Features
Setup is fast and simple with pus
button calibration and LCD display
Offered in three measurement ranges
up to 10m with 2” transducer
6-segment LCD display indicates
level in inch or centimeter values
7.6 cm minimum beam width for
applications with restricted space
Selectable display indicates level in air
gap or liquid height
PC/ABS enclosure rated NEMA 4X
with rugged PVDF transducer
Fail-safe intelligence with diagnostic
feedback for easy troubleshooting
Rear View Shown
65
IP
DS300350-REV:A

Related parts for LU83-5101

LU83-5101 Summary of contents

Page 1

... Resolution: LU81/83: 0.039" (1 mm) LU84: 0.078" (2 mm) Beam width: 3" (7.6 cm) dia. Dead band: LU81: 8" (20 cm) LU83: 8" (20 cm) LU84: 12" (30 cm) Display type: LCD, 6-digit Display units: Inch percent Display mode: Air gap or liquid height ...

Page 2

EchoSpan EchoSpan Side View Menu SELECT / FAST Button UNITS SELECT Display Units Inches Centimeters Percentage Display To LC52 Relay Controller To PLC We Do Your Level Best TM Ultrasonic Level Transmitter DISPLAY TOP MENU TANK SAFE TGCAL SELECT SELECT ...