... Equipment for Av controlling — process fluids 2. Equipment for pneumatics 2.1 Indication according to the international standards (1) Standards conforming to ISO 6358: 1989 : Pneumatic fluid power—Components using compressible fluids— Determination of flow-rate characteristics JIS B 8390: 2000 : Pneumatic fluid power—Components using compressible fluids— ...
Page 2
Sonic conductance [dm /(s·bar Critical pressure ratio [— Upstream pressure [MPa Downstream pressure [MPa Temperature [°C] Note) Formula of subsonic flow is the elliptic analogous curve. Flow ...
Page 3
... Standards conforming to JIS B 8390: 2000: Pneumatic fluid power—Components using compressible fluids— Determination of flow rate characteristics Equipment standards: JIS B 8373: 2 port solenoid valve for pneumatics JIS B 8374: 3 port solenoid valve for pneumatics JIS B 8375: 4 port, 5 port solenoid valve for pneumatics ...
Page 4
Cv 2.3 Flow coefficient factor The United States Standard ANSI/(NFPA)T3.21.3:1990: Pneumatic fluid power—Flow rating test procedure and reporting method for fixed orifice components defines the Cv factor of flow coefficient by the following formula which is based on the test ...
Page 5
Solenoid Valves Flow Characteristics Conversion of flow coefficient: – Here, Kv factor: Value of the clean water flow rate represented by the m pressure difference is 1 bar. Cv factor ...
Page 6
Test method By attaching the equipment for testing with the test circuit shown in Fig. (3) and running water 40°C, measure the flow rate with a pressure difference of 0.075 MPa. However, the pressure difference needs ...
Page 7
Flow Characteristics Note) Use this graph as a guide. In the case of obtaining an accurate flow rate, refer to front matter pages ø For Air (Orifice size: 10 mm, Minimum operating pressure differential 0.99 0.9 0.8 ...
Page 8
For Water 1,000 500 400 300 200 100 0.02 0.03 0.032 0.04 0.05 0.06 0.07 0.08 0.09 0.1 0.055 Pressure differential Flow Characteristics How to read the graph When a water flow ...
Page 9
Applicable Fluid Check List Pilot Operated 2 Port Solenoid Valve Normally closed (N.C.) Option Symbol and Components Option Seal Material symbol material Body: Shading coil NBR Standard type A FKM Note 1) Brass (C37) or CAC407/Cu B EPDM D FKM ...
Page 10
Glossary of Terms Pressure Terminology 1. Maximum operating pressure differential The maximum pressure differential (the difference between the inlet and outlet pressure) which is allowed for operation, with the valve closed. When the downstream pressure is 0 MPa, this becomes ...
Page 11
Pilot Operated 2 Port Solenoid Valve Series For Water, Oil, Air Single Unit Valve Normally closed (N.C.) Normally open (N.O.) Solenoid Coil Coil: Class B, Class H Rated Voltage 100 VAC, 200 VAC, 110 VAC, 220 VAC, 240 VAC, 230 ...
Page 12
Pilot Operated 2 Port Solenoid Valve Table (1) Model and Solenoid Coil Type Select the coil type from and refer to “How to Order” below. Voltage type AC Coil insulation type Class B Class H (Solenoid valve ...
Page 13
... Orifice size Port size (mmø VXD2130-02 (8A) 10 VXD2130- (10A) 15 VXD2140-03 Thread 10 VXD2130- (15A) 15 VXD2140- (20A) 20 VXD2150-06 VXD2260-10 1 (25A) 25 VXD2270-32 32A 35 Flange VXD2380-40 40A 40 50A 50 VXD2390-50 Note) Weight of grommet type. Add 10 g for conduit for DIN terminal, and 60 g for terminal type respectively. ...
Page 14
Pilot Operated 2 Port Solenoid Valve DC/AC (except VXD VXD2130 AC/Class B) AC/Class B coil (with VXD a full-wave rectifier) ∗ The AC (Class B) coil for VXD2130 comes with a full-wave rectifier. Model Refer to “Table (1)” shown below ...
Page 15
... VXD2130-02 (8A VXD2130- (10A VXD2140-03 Thread 10 VXD2130-04 1 (15A VXD2140-04 3 (20A) 20 VXD2150-06 4 VXD2260-10 1 (25A) 25 VXD2270-32 32A 35 Flange VXD2380-40 40A 40 50A 50 VXD2390-50 Note) Weight of grommet type. Add 10 g for conduit for DIN terminal, and 60 g for terminal type respectively. • Refer to “Glossary of Terms” on front matter 10, for details on the max. operating pressure differential and the max. system pressure. ...
Page 16
Pilot Operated 2 Port Solenoid Valve DC/AC (except VXD VXD2130 AC/Class B) AC/Class B coil (with VXD a full-wave rectifier) ∗ The AC (Class B) coil for VXD2130 comes with a full-wave rectifier. Model Refer to “Table (1)” shown below ...
Page 17
... Model/Valve Specifications Normally closed (N.C.) Orifice size Port size (mmø) 1 VXD2130-02 (8A VXD2130- (10A) VXD2140-03 15 Thread 10 VXD2130- (15A) 15 VXD2140- (20A) 20 VXD2150-06 Orifice size Port size (mmø) VXD2260-10 Thread 1 (25A) 25 VXD2270-32 32A 35 Flange VXD2380-40 40A 40 50A 50 VXD2390-50 Note) Weight of grommet type. Add 10 g for conduit for DIN terminal, and 60 g for terminal type respectively. ...
Page 18
Pilot Operated 2 Port Solenoid Valve VXD DC AC/Class B coil (with VXD a full-wave rectifier) ∗ The AC (Class B) coil for VXD2130 comes with a full-wave rectifier. Model Refer to “Table (1)” shown below for availability. Refer to ...
Page 19
... VXD21/22/23 Series Construction Normally closed (N.C.) Body material: Brass (C37) (32A or more: CAC407), Stainless steel VXD2130 VXD2140/2150/2260 (10A) !3 (15A to 25A OUT VXD2270/2380/2390 (32A to 50A Operation <Valve opened> When the coil !1 is energized, the armature assembly o is attracted into the core of the tube assembly i and the pilot valve A opens. Then the pressure in the pressure action chamber B falls to open the main valve C. < ...
Page 20
Pilot Operated 2 Port Solenoid Valve Dimensions VXD2130 Normally closed (N.C.): G Grommet: (67) (52) Approx. 300 I 19.5 (7.5) OUT 1/4, 3/8, 1 DIN terminal Cable ø6 to ø12 ...
Page 21
... L 24 44 19.5 29 51 22.5 (mm) Model Normally closed Normally open VXD2140 VXD2142 VXD2150 VXD2152 74 51 45.5 VXD2260 VXD2262 81 58 49.5 ∗ Coil with a full-wave rectifier (electrical option “R”) C Conduit: Approx. 280 Port size T Conduit terminal 1/2 R ...
Page 22
Pilot Operated 2 Port Solenoid Valve Dimensions VXD2270/2380/2390 Normally closed (N.C.): VXD2272/2382/2392 Normally open (N.O.): G Grommet Conduit: Approx. 280 1/2 T Conduit terminal 1/2 Q Model Applicable ...