GP46
Max. display pressure
Symbol
Symbol
46
10
Outside diameter
Unit: MPa
ø42.5
1.0
Size
GP46
Standard Specifications
Note 1) Indicates the condition at the lower pressure limit. Use a pipe tape for sealing. Recommended tightening torque: R 1/8:
Note 2) Water is not an acceptable fluid. When using the other fluids, please consult with SMC for compatibility information
Note 3) Set value of pressure switch is indicated by pointer (green). It is the point where the circuit between N.O. (white) and
Note 4) Make sure to provide a minimum difference of 0.1 MPa between the set pressure and the operating pressure (including
Note 5) Maximum error value: Add the pressure gauge indicator error of 0.03 MPa to the setting needle error.
Micro-switch Rated Voltage
Model (Standard)
Note 1) Do not apply pressure more than the maximum display pressure. This will cause a malfunction.
GP46-10-01 to 02
GP46-10-01 to 02L2
GP46-10-01 to 02L5
Rated voltage
Operating current range
10
Set between 7 and 9 N·m, R 1/4: 12 and 14 N·m respectively.
concerning corrosion.
COM (black) is turned off during pressure decrease. To set the value, turn needle in clockwise position to the correct
value. When setting; if desired set position has been passed, turn needle in a counterclockwise direction back again
beyond the desired value and then once again return needle in a clockwise direction stopping at the desired value. Value
must be set while needle is traveling in a clockwise direction.
the pressure drop). If the difference is smaller, it could lead to improper operation. Refer to page 14-11-15 for details on
how to set the setting needle. Use caution: Operating pressure should be the sum of the pressure of the setting needle
error (±0.05 MPa), the hysteresis (0.07 MPa), and the display accuracy (±0.05 MPa) on the set pressure value, or the
circuit between N.O. (white) and COM (black) may not turn ON while pressure is increasing.
Type
Ambient and fluid temperature
Indicated pressure range
Port size
Fluid
Indication precision
Setting range
Hysteresis
Pointer error
Contact
Wiring
Indicator light
Attachment:
With cover ring assembly
Weight (kg)
Model
Symbol
How to Order
(2)
Connection thread
01
02
Symbol
01 M
Option
(1)
Load
Nil
M
Model
(5)
(3)(4)
R
R
Size
With M5 (Female thread)
1 8
1 4
Nil
L2
L5
L2
Specifications
Other versions of this unit can be made on a made-to-order basis. Please consult with SMC
for details, as delivery times may be extended.
Neon light (100 VAC/220 VAC)
Pressure range
Without indicator light
AC
DC
C
0 to 1.0
LED/24 VDC
Indicator light
MPa
C
0.01 to 0.5 A
X201
30 VDC
(1)
Without light: 1ab (Normally open/ Normally closed)
R 1/8, 1/4 (Option M: with M5 female thread)
±0.08 MPa (–5 to 60°C) No freezing
Indication
Lead wire (Length: 300 mm)
With light: 1a (Normally open)
Light emitting diode (LED)
Note) Option C1 (Clear cover has protrusion.
MPa
Symbol
–5 to 60°C (No freezing)
±0.05 MPa (5 to 40°C)
Pressure Gauge Guide
unit
Attachment
(Cover ring assembly)
Part no.: 1305104-4A
Load resistant
Nil
Note 1) X3 (Wetted parts stainless steel)
Note 2) Part number for pressure gauge
0.01 to 0.3 A
Symbol
C
Back side thread
X201 Lead wire length 3 m
Option
/ Clear cover is removable.) is not
compliant.
125 VAC
Nil
1 to 0.8 MPa
0 to 1.0 MPa
±0.03 MPa
Neon light
0.07 MPa
specification is not available.
with MPa·psi units is G46-P∗∗-
∗∗-X30. This will no longer be
sold for use in Japan after the
new Weight and Measure Act
has been implemented (Octo-
ber, 1999).
Without cover ring assembly
Clear cover has no protrusion.
(Clear cover is irremovable.)
GP46
0.12
Air
Connection
Specifications
R
R
thread
Specifications
1
1
4
8
O.D.: ø42
0.01 to 0.2 A
250 VAC
14-11-13
Note
F.R.L.
AV
AU
AF
AR
IR
VEX
AMR
ITV
IC
VBA
VE„
VY1
G
PPA
AL

Related parts for GP46-10-N02L5-C

GP46-10-N02L5-C Summary of contents

Page 1

... Pressure range Model MPa GP46-10- GP46-10-01 to 02L2 0 to 1.0 GP46-10-01 to 02L5 Note 1) Do not apply pressure more than the maximum display pressure. This will cause a malfunction. Micro-switch Rated Voltage Load Rated voltage 30 VDC Operating current range ...

Page 2

... ON when the pressure becomes lower than the set pressure. 14-11-14 Dimensions GP46 Pointer (Green) Setting screw ( ): R 1/4 GP46: With cover ring assembly (For panel mounting) Clear cover is not removable. Load M48 x 2 Limit indicator Indicator light Panel cut dimensions Plate thickness Max ...

Related keywords