PIC16F1933-I/SO Microchip Technology Inc., PIC16F1933-I/SO Datasheet - Page 278

no-image

PIC16F1933-I/SO

Manufacturer Part Number
PIC16F1933-I/SO
Description
28 SOIC .300in TUBE, 7KB Flash, 256B RAM, 256B EEPROM, LCD, 1.8-5.5V
Manufacturer
Microchip Technology Inc.
Datasheet

Specifications of PIC16F1933-I/SO

A/d Inputs
11-Channel, 10-Bit
Comparators
2
Cpu Speed
8 MIPS
Eeprom Memory
256 Bytes
Input Output
25
Interface
I2C/SPI/UART/USART
Memory Type
Flash
Number Of Bits
8
Package Type
28-pin SOIC
Programmable Memory
7K Bytes
Ram Size
256 Bytes
Speed
32 MHz
Timers
4-8-bit, 1-16-bit
Voltage, Range
1.8-5.5 V
Lead Free Status / Rohs Status
RoHS Compliant part

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PIC16F1933-I/SO
Manufacturer:
MICROCHIP
Quantity:
2 000
Part Number:
PIC16F1933-I/SO
Manufacturer:
MICROCHIP
Quantity:
216
Part Number:
PIC16F1933-I/SO
Manufacturer:
MICROCHI
Quantity:
20 000
PIC16F193X/LF193X
23.6.13.1
During a Start condition, a bus collision occurs if:
a)
b)
During a Start condition, both the SDA and the SCL
pins are monitored.
If the SDA pin is already low, or the SCL pin is already
low, then all of the following occur:
• the Start condition is aborted,
• the BCLIF flag is set and
• the MSSP module is reset to its Idle state
The Start condition begins with the SDA and SCL pins
deasserted. When the SDA pin is sampled high, the
Baud Rate Generator is loaded and counts down. If the
SCL pin is sampled low while SDA is high, a bus colli-
sion occurs because it is assumed that another master
is attempting to drive a data ‘1’ during the Start
condition.
FIGURE 23-33:
DS41364D-page 278
(Figure 23-32).
SDA or SCL are sampled low at the beginning of
the Start condition (Figure 23-32).
SCL is sampled low before SDA is asserted low
(Figure 23-33).
SDA
SCL
SEN
BCLIF
S
SSPIF
Bus Collision During a Start
Condition
BUS COLLISION DURING START CONDITION (SDA ONLY)
condition if SDA = 1, SCL = 1
Set SEN, enable Start
SDA sampled low before
Start condition. Set BCLIF.
S bit and SSPIF set because
SDA = 0, SCL = 1.
SDA goes low before the SEN bit is set.
Set BCLIF,
S bit and SSPIF set because
SDA = 0, SCL = 1.
Preliminary
SSPIF and BCLIF are
cleared by software
If the SDA pin is sampled low during this count, the
BRG is reset and the SDA line is asserted early
(Figure 23-34). If, however, a ‘1’ is sampled on the SDA
pin, the SDA pin is asserted low at the end of the BRG
count. The Baud Rate Generator is then reloaded and
counts down to zero; if the SCL pin is sampled as ‘0’
during this time, a bus collision does not occur. At the
end of the BRG count, the SCL pin is asserted low.
Note:
SEN cleared automatically because of bus collision.
SSP module reset into Idle state.
The reason that bus collision is not a factor
during a Start condition is that no two bus
masters can assert a Start condition at the
exact same time. Therefore, one master
will always assert SDA before the other.
This condition does not cause a bus colli-
sion because the two masters must be
allowed to arbitrate the first address fol-
lowing the Start condition. If the address is
the same, arbitration must be allowed to
continue into the data portion, Repeated
Start or Stop conditions.
SSPIF and BCLIF are
cleared by software
 2009 Microchip Technology Inc.

Related parts for PIC16F1933-I/SO