PW102BA1U158 Eaton / Control Automation, PW102BA1U158 Datasheet - Page 17

no-image

PW102BA1U158

Manufacturer Part Number
PW102BA1U158
Description
UPS, EPDU BA 5-20 5-20 (12)
Manufacturer
Eaton / Control Automation
Datasheet

Specifications of PW102BA1U158

Dimensions
19.0 × 1U × 4.5 In.
Length, Cord
9 ft.
Mounting Type
Horizontal
Number Of Outlets
(12) 5-20
Power, Rating
1.92 kW
Special Features
BA
Monitored ePDU
• Prevent accidental disconnection of power input cable
• Connects to any standard C20 power inlet with side screws
• Cable ties provide the highest level of retention
• Flexible hole pattern accommodates any type of plug
C20 Inlet Cable Restraint
Part Number
Max kW
Input Plug
Function
Cord
Orientation
Receptacles
Dimensions WxHxD
Part Number
Max kW
Input Plug
Function
Cord
Orientation
Receptacles
Dimensions WxHxD
SUB-HRDWARE-032
PW306MI2U166
5.76
L21-20P
MI
9’
2U
IEC60320 C13 (18),
IEC60320 C19 (3)
19
PW309MI2U167
8.65
L21-30P
MI
9’
2U
IEC60320 C13 (18),
IEC60320 C19 (3)
19
X
X
3.5
3.5
X
X
13.5
13.5
®
ePDU
Focusing On High Density Power Demands and Trends:
Today’s ever changing technology has brought the need for high-density
IT equipment, bringing forth the demand for more unique power solutions.
The majority of data centers are looking to high-density blade servers, which
can provide superior levels of performance and reliability. Not only are they
more superior they take up a fraction of the space compared to the traditional
servers. Blade servers were designed to pack greater processing power into
a more compact area, resulting in larger quantities of data storage per square
foot. As with every leap in technology usually new problems arise. One very
signifi cant problem data centers are facing with the high-density trend, is
powering these dense racks of sophisticated IT equipment. Blade servers
can have as many as 8 power supplies, each with C19 connections.
Focusing on the power needs of these high-density applications comes new
strides in power management. Eaton’s high-density ePDUs provide a way to
distribute power to these mission critical devices. Traditionally a single rack
of equipment would have one or two 20 amp power strips mounted in them.
In more recent years it has gone to one or two 30 amp strips. The newest
generations of power distribution solutions is a high-density strip that provides
50-60 amps. This approach allows an entire rack of equipment to be powered
from a single power cord input. Thus reducing cabling costs and cable clutter
when compared to mounting multiple power strips in an electronic enclosure.
Eaton’s innovative high-density ePDUs are ideal for the most power intense
environments.
®
Power Tip:
Part Number
Max kW
Input Plug
Function
Cord
Orientation
Receptacles
Dimensions WxHxD
PW110MI2U168
9.98
IEC60309 360P6W IEC60309 460P9W
MI
10’
2U
IEC60320 C19 (12)
19
X
3.5
X
9.5
WWW.EPDU.COM 1.800.356.5794
PW317MI1U141
17.29
MI
10’
2U
IEC60320 C19 (12)
19
X
3.5
X
9.5
17