PW102BA1U158 Eaton / Control Automation, PW102BA1U158 Datasheet - Page 18

no-image

PW102BA1U158

Manufacturer Part Number
PW102BA1U158
Description
UPS, EPDU BA 5-20 5-20 (12)
Manufacturer
Eaton / Control Automation
Datasheet

Specifications of PW102BA1U158

Dimensions
19.0 × 1U × 4.5 In.
Length, Cord
9 ft.
Mounting Type
Horizontal
Number Of Outlets
(12) 5-20
Power, Rating
1.92 kW
Special Features
BA
18
V55 ePDU
ePDU
The ePDU
integrates current and temperature monitoring into a
60 amp vertical strip. This three phase solution allows for
branch circuit monitoring of up to 48 outlets over Ethernet.
The confi guration options include C13 or C19 outlets and
various plug types. Output voltage is 208 volts to provide
power supply effi ciency. The outlets are connected to six
branch circuit breaker sections, with load current
monitoring for each section. There is a local LED amps
display and the unit is Ethernet enabled for web browser or
SNMP monitoring. There is integrated temperature for two
locations with optional probes.
Features:
Detachable mounting brackets allow for several
mounting options. Tool-less mounting hardware included
Six 2 pole 20 amp circuit breakers are located on the
front panel. UL 289 Listed electromagnetic circuit
breakers. Meets branch circuit breaker requirements
Breaker switch is fl ush with panel when “on” to prevent
accidental shut off and shows red when in the off or
tripped position
Power input cable length options of 9 or 15 feet
Power input option of terminal block input
C13 versions have (48) IEC 60320 type C13 receptacle.
Each circuit breaker protects eight receptacles
C19 versions have (24) IEC 60320 type C19 receptacles
C39 versions have (12) C19 and (24) C13 receptacles.
Each circuit breaker protects six receptacles
Input options of 50 or 60 amps
Single or Three phase inputs are optional
Ideal for blade servers or other power demanding
applications
®
®
V55
EATON CORPORATION Enclosure Power Distribution Units
V55 series high density power distribution unit
®
50 = 50 amp input and plug
60 = 60 amp input and plug
C39 = (12) C19, (24) C13
C13 = (48) C13
C19 = (24) C19
2 = 2 pole plus ground input plug
(Line-Line-Ground) 1 phase
3 = 3 pole plus ground input plug
(Line-Line-Line-Ground) 3 phase delta
4 = 4 pole plus ground input plug
(Line-Line-Line-Neutral-Ground) 3 phase wye
ePDU
V 5 5
Red color indicates when the
breaker is off. Circuit breaker
switch is fl ush in the “ON” position
to prevent accidental turn off.
Power input option of terminal
block input
®
V55 part number guide
-
-
-
Cable Length
03 - 3 feet
09 - 9 feet
15 - 15 feet
HW - Hard Wire