ICL3227ECAZA Intersil, ICL3227ECAZA Datasheet - Page 10

IC 1DRVR/1RCVR RS232 3V 16-SSOP

ICL3227ECAZA

Manufacturer Part Number
ICL3227ECAZA
Description
IC 1DRVR/1RCVR RS232 3V 16-SSOP
Manufacturer
Intersil
Type
Transceiverr
Datasheet

Specifications of ICL3227ECAZA

Number Of Drivers/receivers
1/1
Protocol
RS232
Voltage - Supply
3 V ~ 5.5 V
Mounting Type
Surface Mount
Package / Case
16-SSOP
Device Type
Transceiver
Interface Type
RS232
No. Of Drivers
1
Supply Voltage Range
3V To 5.5V
Driver Case Style
SSOP
No. Of Pins
16
Operating Temperature Range
0°C To +70°C
Svhc
No SVHC
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ICL3227ECAZA
Manufacturer:
INTERSIL
Quantity:
5 693
Part Number:
ICL3227ECAZA-T
Manufacturer:
INTERSIL
Quantity:
8 294
When using both manual and enhanced automatic
powerdown (FORCEON = 0), the ICL32XXE won’t power up
from manual powerdown until both FORCEOFF and
FORCEON are driven high, or until a transition occurs on a
receiver or transmitter input. Figure 5 illustrates a circuit for
ensuring that the ICL32XXE powers up as soon as
FORCEOFF switches high. The rising edge of the Master
Powerdown signal forces the device to power up, and the
ICL32XXE returns to enhanced automatic powerdown mode
an RC time constant after this rising edge. The time constant
isn’t critical, because the ICL32XXE remains powered up for
30 seconds after the FORCEON falling edge, even if there
are no signal transitions. This gives slow-to-wake systems
(e.g., a mouse) plenty of time to start transmitting, and as
long as it starts transmitting within 30 seconds both systems
remain enabled.
INVALID Output
The INVALID output always indicates (see Table 2) whether
or not 30µs have elapsed with invalid RS-232 signals (see
Figures 6 and 8) persisting on all of the receiver inputs,
giving the user an easy way to determine when the interface
block should power down. Invalid receiver levels occur
whenever the driving peripheral’s outputs are shut off
(powered down) or when the RS-232 interface cable is
disconnected. In the case of a disconnected interface cable
where all the receiver inputs are floating (but pulled to GND
FIGURE 4. CONNECTIONS FOR MANUAL POWERDOWN
FIGURE 5. CIRCUIT TO ENSURE IMMEDIATE POWER UP
MANAGEMENT
POWER
CPU
UNIT
LOGIC
PWR
MGT
WHEN NO VALID RECEIVER SIGNALS ARE
PRESENT
WHEN EXITING FORCED POWERDOWN
UART
MASTER POWERDOWN LINE
I/O
FORCEOFF
FORCEON
INVALID
FORCEOFF
10
ICL32XXE
0.1µF
ICL32XXE
FORCEON
ICL3225E, ICL3227E, ICL3245E
1MΩ
by the internal receiver pull down resistors), the INVALID
logic detects the invalid levels and drives the output low. The
power management logic then uses this indicator to power
down the interface block. Reconnecting the cable restores
valid levels at the receiver inputs, INVALID switches high,
and the power management logic wakes up the interface
block. INVALID can also be used to indicate the DTR or
RING INDICATOR signal, as long as the other receiver
inputs are floating, or driven to GND (as in the case of a
powered down driver).
Enhanced Automatic Powerdown
Even greater power savings is available by using these devices
which feature an enhanced automatic powerdown function.
When the enhanced powerdown logic determines that no
transitions have occurred on any of the transmitter nor receiver
inputs for 30 seconds, the charge pump and transmitters
powerdown, thereby reducing supply current to 1µA. The
ICL32XXE automatically powers back up whenever it detects a
transition on one of these inputs. This automatic powerdown
feature provides additional system power savings without
changes to the existing operating system.
Enhanced automatic powerdown operates when the
FORCEON input is low, and the FORCEOFF input is high.
Tying FORCEON high disables automatic powerdown, but
manual powerdown is always available via the overriding
FORCEOFF input. Table 2 summarizes the enhanced
automatic powerdown functionality.
Figure 7 illustrates the enhanced powerdown control logic.
Note that once the ICL32XXE enters powerdown (manually
or automatically), the 30 second timer remains timed out
T_IN
R_IN
FIGURE 6. DEFINITION OF VALID RS-232 RECEIVER LEVELS
FIGURE 7. ENHANCED AUTOMATIC POWERDOWN LOGIC
-0.3V
-2.7V
2.7V
0.3V
DETECT
DETECT
EDGE
EDGE
INVALID LEVEL - INVALID = 0
VALID RS-232 LEVEL - INVALID = 1
VALID RS-232 LEVEL - INVALID = 1
FORCEON
INDETERMINATE
INDETERMINATE
FORCEOFF
30s
TIMER
R
S
February 27, 2006
AUTOSHDN
FN4900.9

Related parts for ICL3227ECAZA