CAT1024ZI42 ON Semiconductor, CAT1024ZI42 Datasheet - Page 5

no-image

CAT1024ZI42

Manufacturer Part Number
CAT1024ZI42
Description
Supervisory Circuits 2K bit 4.2V Ind Temp
Manufacturer
ON Semiconductor
Datasheet

Specifications of CAT1024ZI42

Number Of Voltages Monitored
5
Monitored Voltage
3 V, 3.3 V, 5 V
Undervoltage Threshold
4.25 V to 4.5 V
Output Type
Open Collector / Drain
Manual Reset
Resettable
Watchdog
No Watchdog
Power-up Reset Delay (typ)
200 mS
Supply Voltage (max)
5 V, 3.3 V, 3 V
Supply Voltage (min)
2.7 V
Supply Current (typ)
3000 uA
Maximum Power Dissipation
1000 mW
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Package / Case
MSOP-8
Minimum Operating Temperature
- 40 C
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
CAPACITANCE
T
AC CHARACTERISTICS
V
Memory Read & Write Cycle
Notes:
(1) This parameter is characterized initially and after a design or process change that affects the parameter. Not 100% tested.
(2) Test Conditions according to “AC Test Conditions” table.
(3) The write cycle time is the time from a valid stop condition of a write sequence to the end of the internal program/erase cycle. During the
© 2009 SCILLC. All rights reserved.
Characteristics subject to change without notice
A
CC
Symbol
Symbol
C
t
t
t
t
t
= 25ºC, f = 1.0 MHz, V
HD; STA
HD; DAT
SU; DAT
SU; STO
t
write cycle, the bus interface circuits are disabled, SDA is allowed to remain high and the device does not respond to its slave address.
C
SU; STA
t
t
BUF
t
f
t
WC
OUT
= 2.7 V to 5.5 V and over the recommended temperature conditions, unless otherwise specified.
t
HIGH
LOW
t
t
t
SCL
R
F
IN
SP
AA
DH
(1)
(1)
(1)
(3)
(1)
(1)
Test
Output Capacitance
Input Capacitance
Parameter
Clock Frequency
Input Filter Spike Suppression (SDA, SCL)
Clock Low Period
Clock High Period
SDA and SCL Rise Time
SDA and SCL Fall Time
Start Condition Hold Time
Start Condition Setup Time (for a Repeated Start)
Data Input Hold Time
Data Input Setup Time
Stop Condition Setup Time
SCL Low to Data Out Valid
Data Out Hold Time
Time the Bus must be Free Before a New Transmission Can Start
Write Cycle Time (Byte or Page)
CC
= 5 V
(2)
5
Test Conditions
V
V
OUT
IN
= 0 V
= 0 V
Min
100
1.3
0.6
0.6
0.6
0.6
1.3
50
0
CAT1024, CAT1025
Max
Max
400
900
100
300
300
8
6
5
Doc. No. MD-3008 Rev. R
Units
Units
kHz
ms
pF
pF
µs
µs
µs
µs
ns
ns
ns
ns
ns
µs
ns
ns
µs

Related parts for CAT1024ZI42