PEB24911HV13 Lantiq, PEB24911HV13 Datasheet - Page 128

no-image

PEB24911HV13

Manufacturer Part Number
PEB24911HV13
Description
Manufacturer
Lantiq
Datasheet

Specifications of PEB24911HV13

Lead Free Status / Rohs Status
Supplier Unconfirmed

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PEB24911HV13
Manufacturer:
RENESAS
Quantity:
3 897
6.1
U-Interface Registers
*) read-back function for test use
l
Table 18
Reg Name Access
LP_SEL
U-Interface Registers
OPMODE WR
MFILT
M4RMASK
Data Sheet
LP_SEL
OPMODE
MFILT
M4RMASK
M4WMASK
TEST
LOOP
FEBE
NEBE
BERC
Register Summary
WR
WR
WR
ADR
1C
Register Map Reference Table
0F
00
01
07
08
10
11
12
13
14
H
H
H
H
H
H
H
H
H
H
H
M56 FILTER
7
0
0
0
0
Address
1C
00
01
07
H
H
H
H
DLB
6
0
0
1
TRANS
FEBE
BERC Counter Value (Bit 15-8)
BERC Counter Value (Bit 7-0)
5
0
BER
Reset
Value
00
02
14
00
FEBE Counter Value
NEBE Counter Value
M4 FILTER
M4 Read Mask Bits
M4 Write Mask Bits
H
H
H
H
IOM
118
U/
4
0
0
®
CCRC
Comment
Line Port Selection Reg.
line port 0 is selected by
default
Opmode Register
M-Bit Filter Register
– EOC in automode
– M4 CRC checked vs. IOM
– M4 TLL checked vs. SM
– M56 CRC checked
M4 Read Mask Register
any M4-bit change causes a
MON-2 message
3
0
0
1
Tones
LBBD
+-1
2
0
0
EOC FILTER
LN2
LB2
1
1
0
Register Description
40KHz
LN1
LB1
0
0
PEF 24911
WR/RD*
WR/RD*
WR/RD*
WR/RD*
WR/RD*
WR/RD*
WR/RD*
®
WR/RD
2001-07-16
RD
RD
RD
Page
No.
121
121
122
125
Ch.
1/4
1
1
1
1
1
4
4
4
4
4

Related parts for PEB24911HV13