Specifications of A3PE-BRD600-SKT

Processor To Be Evaluated
ProASIC3/E
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
PLL Parts/Usage on ProASIC3
Power Supplies
ProASIC3/E Starter Kit User’s Guide and Tutorial
Instructions for PLL Activation on ProASIC3 Starter Kit Board
In order to use the PLLs on the ProASIC3 starter kit board, power must be applied to their respective analog supply
rails. For the west side PLL, known as PLF, the V
same is true for V
must be connected to ground. We do not connect these voltages by default on the board for three reasons:
1.
2.
3.
A variety of valid connections are possible. Two examples are as follows:
1.
2.
To facilitate end users, we will be supplying jumper wires with selected production versions of the kit to allow end users
to quickly connect and disconnect these voltage supply rails. If a user has lost the jumper wires or has a production kit
without jumper wires, it is a simple matter of soldering short insulated connecting wire to the appropriate header pins on
the J14A and J14C headers.
A 9 V power supply is provided with the kit
board to illustrate the many ways that differing voltage banks may be supported with ProASIC3 and ProASIC3E
The PLC analog voltage rails are not available on A3P devices, only on A3PE in the PQ208 package. Only the west
side PLL, namely PLF, is available on A3P devices in PQ208. In A3P devices, the pins are used as general I/Os. The
same board is used for A3PE and A3P devices.
We want to demonstrate the lowest possible power consumption for the part. Perpetually powering the PLL lines
would not achieve that.
It is easy to connect the appropriate pins together when desired. That is why we make the pins available on the
headers.
For PLF, connect pin 27 (V
For PLC, (A3PE only) connect pin 131 (V
CCPLC
of the PLL on the east side, known as PLC. In addition, the V
CCPLF
) to pin 36 (V
(Figure
CCPLC
CCPLF
2-2). There are many power supply components in the starter kit
CC
) to pin 142 (V
), and pin 25 (V
line must be connected to V
CC
COMPLF
), and pin 133 (V
) to pin 17 (GND).
CC
PLL Parts/Usage on ProASIC3
COMPLF
, which is held at 1.5 V. The
COMPLC
and V
) to pin 141 (GND).
COMPLC
lines