3601-95B-40 IEE (INDUSTRIAL ELECTRONIC ENGINEERS), 3601-95B-40 Datasheet - Page 33

Vacuum Fluorescent Display Panel

3601-95B-40

Manufacturer Part Number
3601-95B-40
Description
Vacuum Fluorescent Display Panel
Manufacturer
IEE (INDUSTRIAL ELECTRONIC ENGINEERS)
Datasheet

Specifications of 3601-95B-40

Resolution
2 X 20
Character Format
Dot Matrix
Viewing Area (h X W)
17.67mm X 93.8mm
Supply Current
370mA
Interface Type
Serial, Parallel
Operating Temperature Range
0°C To +55°C
Rohs Compliant
Yes
04/10/02
4.5
Industrial Electronic Engineers, Inc.
Van Nuys, California
Screen Control Codes (Cont.)
[A
36h
38h
39h
3Ch
3Dh
37h
3Ah
3Bh
*
0
(RS) = High for the following Control Codes]
Erase Line Data With End Blink
Erases 1 or more lines of data (with blink) using a 2 byte command consisting of control code 36h
and blink field/line data.
Bits 0 through 3 retain (0) or erase (1) lines 0 through 3 respectively.
For example:
Blink Field ON/OFF
D 7 D 6 D 5 D 4
X
X
Underbar On
Sets the underbar to ON at the current character position.
Underbar Off
Sets the underbar to OFF at the current character position.
Screen Saver On
Sets the display screen to brightness level 07h (dimmest) after a 10 minute idle time.
(Any new control or data input resets the Screen Saver function for another 10 minute cycle, The
Screen Saver function remains active.)
Screen Saver Off
Restores the screen display to previously established brightness level(s) and deactivates the
Screen Saver function. (Default)
Set Carriage Return and Line Feed Definitions
Sets the functions of the Line Feed (0Ah) and Carriage Return (0Dh) commands using a 2 byte
command consisting of control code 37h and the function ID.
Set Right to Left Data Entry
Reverses data entry mode for use with Hebrew Character Set.
Set Left to Right Data Entry
Restores data entry mode to normal ASCII. (Default)
Applies to 036X2–151–05240 & 036X2-160-05440 only. Unassigned for all other models.
X X X
X X X
Function ID
00h
01h
02h
03h
*
*
Definition
LF = LF
LF = LF + CR
LF = LF
LF = LF + CR
SCALE
SIZE
Line Position
D 3 D 2 D 1 D 0
0
1
A
0 0 1
1 0 0
CR = CR (Default)
CR = CR
CR = CR + LF
CR = CR + LF
CODE IDENT NO.
N/A
05464
Erase line 0, retain lines 1, 2, 3.
Erase lines 2 & 3, retain lines
0 & 1.
REV
N
SHEET
S036X2–XXX–XXXXX
32 of 49

Related parts for 3601-95B-40