MAX13041ASD+T Maxim Integrated Products, MAX13041ASD+T Datasheet
MAX13041ASD+T
Specifications of MAX13041ASD+T
Related parts for MAX13041ASD+T
MAX13041ASD+T Summary of contents
Page 1
... Mid-Heavy Truck—Clamp 30 Modules Military and Commercial Aircraft BAT Pin Configuration appears at end of data sheet. ________________________________________________________________ Maxim Integrated Products For pricing, delivery, and ordering information, please contact Maxim Direct at 1-888-629-4642, or visit Maxim’s website at www.maxim-ic.com. ♦ Functionally Compatible Pin-to-Pin Replacement for the Philips TJA1041A ♦ ...
Page 2
Fault-Protected High-Speed CAN Transceiver with Low-Power Management and Wake-On CAN ABSOLUTE MAXIMUM RATINGS (All voltages referenced to GND ...................................................................-0.3V to +6V CC I/O V ........................................................................-0.3V to +80V BAT TXD, RXD, STB, EN, ERR .........................................-0.3V to +6V ...
Page 3
Fault-Protected High-Speed CAN Transceiver with Low-Power Management and Wake-On CAN ELECTRICAL CHARACTERISTICS (continued +4.75V to +5.25V +2. I/O values are +5V +3.3V I/O PARAMETER SYMBOL ...
Page 4
Fault-Protected High-Speed CAN Transceiver with Low-Power Management and Wake-On CAN ELECTRICAL CHARACTERISTICS (continued +4.75V to +5.25V +2. I/O values are +5V +3.3V I/O PARAMETER SYMBOL ...
Page 5
Fault-Protected High-Speed CAN Transceiver with Low-Power Management and Wake-On CAN TIMING CHARACTERISTICS (V = +4.75V to +5.25V +2. I/O values are +5V +3.3V I/O PARAMETER Delay TXD ...
Page 6
Fault-Protected High-Speed CAN Transceiver with Low-Power Management and Wake-On CAN (V = +5V +3.3V +12V I/O BAT I SUPPLY CURRENT BAT vs. TEMPERATURE 25 SLEEP MODE -40 -25 ...
Page 7
Fault-Protected High-Speed CAN Transceiver with Low-Power Management and Wake-On CAN (V = +5V +3.3V +12V I/O BAT DIFFERENTIAL OUTPUT VOLTAGE vs. LOAD RESISTANCE 3.6 NORMAL MODE 3.4 3.2 3.0 2.8 2.6 2.4 2.2 ...
Page 8
Fault-Protected High-Speed CAN Transceiver with Low-Power Management and Wake-On CAN (V = +5V +3.3V +12V I/O BAT INH VOLTAGE vs. TEMPERATURE 12 1mA INH 11.8 11.6 11.4 11.2 11.0 10.8 10.6 ...
Page 9
Fault-Protected High-Speed CAN Transceiver with Low-Power Management and Wake-On CAN PIN NAME 1 TXD Data Transmit Input, CMOS Compatible. TXD is internally pulled GND Ground Supply Voltage +4.75V to +5.25V. Bypass ...
Page 10
Fault-Protected High-Speed CAN Transceiver with Low-Power Management and Wake-On CAN V t D(TXD-BUSON) V I(DIF)(BUS) Figure 1. Timing Diagram 47μF +5V + Figure 2. Test Circuit for Timing Characteristics 10 ______________________________________________________________________________________ TXD CANH CANL DOMINANT I(DIF)(BUS) RXD 0.3 V ...
Page 11
Fault-Protected High-Speed CAN Transceiver with Low-Power Management and Wake-On CAN Detailed Description The MAX13041 ±80V fault-protected, high-speed CAN transceiver is intended for high-speed industrial and automotive network applications where high reliability and advanced power management are required. The device ...
Page 12
Fault-Protected High-Speed CAN Transceiver with Low-Power Management and Wake-On CAN In the lowest-power mode, the MAX13041 disables exter- nal voltage regulators to provide a sleep mode for the entire node. The MAX13041 restores power to the node upon a ...
Page 13
Fault-Protected High-Speed CAN Transceiver with Low-Power Management and Wake-On CAN PWON/LISTEN-ONLY MODE STB = H AND STANDBY MODE STB = H AND AND UV CLEARED NOM NOTES: H AND L ARE FLAG SET ...
Page 14
Fault-Protected High-Speed CAN Transceiver with Low-Power Management and Wake-On CAN Table 2. Flag Signaling on ERR INTERNAL FLAG UV No NOM UV No BAT In PWON/listen-only mode (changing from PWON standby, go-to-sleep command, or sleep modes) In standby, go-to-sleep ...
Page 15
Fault-Protected High-Speed CAN Transceiver with Low-Power Management and Wake-On CAN normal mode, prior to the fourth dominant-to-recessive transition on TXD. A low level on ERR indicates a local wake-up has occurred. The bus failure flag is set when the ...
Page 16
Fault-Protected High-Speed CAN Transceiver with Low-Power Management and Wake-On CAN Thermal Shutdown Fault The local failure flag is set when the junction temperature (T ) exceeds the shutdown junction temperature thresh- J old The transmitter is disabled ...
Page 17
Fault-Protected High-Speed CAN Transceiver with Low-Power Management and Wake-On CAN 1.5kΩ 1MΩ DISCHARGE CHARGE-CURRENT- RESISTANCE LIMIT RESISTOR HIGH STORAGE VOLTAGE 100pF CAPACITOR DC SOURCE Figure 6. Human Body ESD Test Model V BAT ...
Page 18
Fault-Protected High-Speed CAN Transceiver with Low-Power Management and Wake-On CAN Pin Configuration TOP VIEW + TXD 1 GND MAX13041 RXD I INH ______________________________________________________________________________________ PROCESS: BiCMOS 14 STB ...
Page 19
Fault-Protected High-Speed CAN Transceiver with Low-Power Management and Wake-On CAN V V I/O INH TXD RXD ERR LEVEL SHIFTING STB EN WAKE ______________________________________________________________________________________ V BAT CC MAX13041 FLAG SIGNALING OPERATING MODE CONTROL WAKE DETECT GND For the latest package ...
Page 20
... Maxim cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim product. No circuit patent licenses are implied. Maxim reserves the right to change the circuitry and specifications without notice at any time. 20 ____________________Maxim Integrated Products, 120 San Gabriel Drive, Sunnyvale, CA 94086 408-737-7600 © 2008 Maxim Integrated Products DESCRIPTION Maxim is a registered trademark of Maxim Integrated Products, Inc ...