Specifications of DHR 500 C10

Operating Frequency Range
DC To 6kHz
Supply Voltage Range Dc
20V To 50V
Sensor Output
Voltage
Accuracy
1%
Response Time
150ms
Svhc
No SVHC (15-Dec-2010)
Current Consumption
30mA
Rohs Compliant
Yes
Accuracy %
1%
Current Transducer DHR-C10
V
V
dCp
dCl
CTI
LEM Components
Notes :
Output polarity with DC input
b
d
Isolation characteristics
-Ipn
Rated Voltage
with IEC 61010-1 acc. to the 61326 standards and following conditions :
R.m.s. voltage for AC insulation test, 50Hz, 1min
Creepage distance
Clearance distance
Comparative tracking index (Group I)
Output in V
- Single insulation
- Over voltage category CAT III
- Pollution degree PD2
- None uniform field
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
10
0
+Ipn
1000
5
11
11
600
m m
m m
kV
V
www.lem.com