XW2Z-100J-A27 Omron, XW2Z-100J-A27 Datasheet - Page 7

no-image

XW2Z-100J-A27

Manufacturer Part Number
XW2Z-100J-A27
Description
SERVO RELAY UNIT CABLES 1M
Manufacturer
Omron
Datasheet

Specifications of XW2Z-100J-A27

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
XW2Z100JA27
*3. Supported only by CJ2M CPU Units with unit version 2.0 or later. A Pulse I/O Module must be mounted.
*4. Cannot be used in Function blocks.
*5. Can be used only in Function blocks.
*6. Supported only by the CJ2M-CPU3@.
Execution Mode
Programming Languages
Function
Blocks
FB Program Area
Tasks
Symbols
(Variables)
Data
Tracing
File Memory
Source/
Comment
Memory
Commu-
nications
Maximum number of definitions
Maximum number of instances
Type of Tasks
Number of Tasks
Type of Symbols
Data Type of Symbols
Maximum Size of Symbol
Array Symbols (Array Variables)
Number of Array Elements
Number of Registrable Network
Symbols (Tags) *6
Length of Network Symbol (Tag)
Name *6
Encoding of Network Symbols (Tags) *6
Memory Capacity
Number of Samplings
Sampling Cycle
Trigger Conditions
Delay Value
Function block program memory,
comment file, program index file,
symbol tables
Logical Ports for
Communications
CIP
Communications
Specification
Items
Logical Ports
Extended Logical
Ports
Class 3
(Connection Type)
UCMM (Non-
connection Type)
Normal Mode
Ladder Logic (LD),
Sequential Function Charts (SFC),
Structured Text (ST), and
Instruction Lists (IL)
256
256
20K steps
Cyclic tasks
Interrupt tasks (Power OFF interrupt tasks, scheduled interrupt tasks, I/O interrupt tasks, and external interrupt
tasks, and input interrupt tasks *3)
Cyclic tasks: 128
Interrupt tasks: 256
(Interrupt tasks can be defined as cyclic tasks to create extra cyclic tasks. Therefore, the total number of cyclic
tasks is actually 384 max.)
* Supported only by the CJ2M-CPU3@.
32k words
One-dimensional arrays
32,000 elements max.
2,000 max.
255 bytes max.
UTF-8
8,000 words (Up to 32k words × 4 banks when EM is specified in CX-Programmer)
Bits = 31, one-word data =16, two-word data = 8, four-word data = 4
1 to 2,550 ms (Unit: 1 ms)
ON/OFF of specified bit
Data comparison of specified word
Data size: 1 word, 2 words, 4 words
Comparison Method: Equals (=), Greater Than (>), Greater Than or Equals (≥), Less Than (<), Less Than or
Equals (≤), Not Equal (≠)
−32,768 to +32,767 ms
Memory Card (128, 256, or 512 Mbytes) (Use the Memory Cards provided by OMRON.)
EM file memory (Part of the EM Area can be converted for use as file memory.)
Capacity: 1 Mbytes
8 ports (Used for SEND, RECV, CMND, PMCR, TXDU, and RXDU instructions.)
64 ports (Used for SEND2, RECV2, CMND2, and PMCR2 instructions.)
Number of connections: 64
Maximum number of clients that can communicate at the same time: 32
Maximum number of servers that can communicate at the same time: 40
• Local symbols: Can be used only within a single task in the PLC.
• Global symbols: Can be used in all tasks in the PLC.
• Network symbols (tags)*: I/O memory in the CPU Unit can be externally accessed using symbols,
• BOOL (bit)
• UINT (one-word unsigned binary)
• UDINT (two-word unsigned binary)
• ULINT (four-word unsigned binary)
• INT (one-word signed binary)
• DINT (two-word signed binary)
• LINT (four-word signed binary)
• UINT BCD (one-word unsigned BCD) *4
• UDINT BCD (two-word unsigned BCD) *4
• ULINT BCD (four-word unsigned BCD) *4
• REAL (two-word floating-point)
• LREAL (four-word floating-point)
• CHANNEL (word) *4
• NUMBER (constant or number) *4
• WORD (one-word hexadecimal)
• DWORD (two-word hexadecimal)
• LWORD (four-word hexadecimal)
• STRING (1 to 255 ASCII characters)
• TIMER (timer) *5
• COUNTER (counter) *5
• User defined data types (data structures)
depending on parameter settings.
CPU11/31
CPU12/32
CJ2M-CPU3@/-CPU1@/-MD21@
CPU13/33
CJ2M-
2,048
2,048
CPU14/34
CPU15/35
7