Auxiliary Area Allocations
Address
A520
A521
A522
A523
A524
A525
A526
A527
A530
A531
A532
A533
A534
A535
A550
A552
00 to 15 Interrupt Counter 0 Counter SV
00 to 15 Interrupt Counter 1 Counter SV
00 to 15 Interrupt Counter 2 Counter SV
00 to 15 Interrupt Counter 3 Counter SV
00 to 15 Interrupt Counter 0 Counter PV
00 to 15 Interrupt Counter 1 Counter PV
00 to 15 Interrupt Counter 2 Counter PV
00 to 15 Interrupt Counter 3 Counter PV
00
01
00 to 15 Slot No. of Motion Control Module for DM Trans-
00 to 15 DM Transfer Size (number of words)
00 to 15 First DM Transfer Source Word
00 to 15 First DM Transfer Destination Word
14
15
00 to 15 Analog Input PV
00
07
08
09
15
Bits
DM Write Request Bit (Coordinator Module to
Motion Control Module)
DM Read Request Bit (Motion Control Module to
Coordinator Module)
fer
Transfer Error Flag
Transfer Busy Flag
Analog Input Status
Name
Used for interrupt input 0 in counter mode.
Sets the count value at which the interrupt task will start. Interrupt
task 000 will start when interrupt counter 0 has counted this num-
ber of pulses.
Setting range: 0000 to FFFF
Used for interrupt input 1 in counter mode.
Sets the count value at which the interrupt task will start. Interrupt
task 001 will start when interrupt counter 1 has counted this num-
ber of pulses.
Setting range: 0000 to FFFF
Used for interrupt input 2 in counter mode.
Sets the count value at which the interrupt task will start. Interrupt
task 002 will start when interrupt counter 2 has counted this num-
ber of pulses.
Setting range: 0000 to FFFF
Used for interrupt input 3 in counter mode.
Sets the count value at which the interrupt task will start. Interrupt
task 003 will start when interrupt counter 3 has counted this num-
ber of pulses.
Setting range: 0000 to FFFF
These words contain the interrupt counter PVs for interrupt input
0 to 3 operating in counter mode.
The counter PV starts decrementing from the counter SV. When
the counter PV reaches the 0, the PV is automatically reset to the
SV.
Range: 0000 to FFFF
DM data transfer is executed from the Coordinator Module to
Motion Control Module when this bit turns ON.
DM data transfer is executed from the Motion Control Module to
Coordinator Module when this bit turns ON.
Specifies the slot number (in 4-digit hexadecimal) for the Motion
Control Module with which DM data is to be transferred.
0001: Motion Control Module #1
0002: Motion Control Module #2
0003: Motion Control Module #3
0004: Motion Control Module #4
Specifies the size, in number of words, of the DM data to be trans-
ferred.
0001 to 01F3 hex (1 to 499 words)
Specifies the first address of the DM transfer source in the Coor-
dinator Module or Motion Control Module.
0000 to 7FFF hex
Specifies the first address of the DM transfer destination in the
Coordinator Module or Motion Control Module.
0000 to 7FFF hex
Turns ON when a DM data transfer error occurs.
Turns ON during DM data transfer and turns OFF when the trans-
fer has been completed.
Contains the value input from the analog input port (using either
the END refresh or immediate refresh) in 4-digit hexadecimal.
The PV range depends on the input range:
• 0 to 10 V:
• 0 to 5 V or 1 to 5 V:
• − 10 to 10 V:
User Adjustment
Completed
Analog Sampling
Started
Factory Adjustment
Data Error
User Adjustment
Data Error
Analog Sampling
Overlap
OFF: Not adjusted
ON: Adjustment completed
OFF: Not started
ON: Started
OFF: No Error
ON: Error (Checked at power ON.)
OFF: No Error
ON: Error (Checked at power ON.)
OFF: Normal sampling
ON: The next sampling operation occurred
before the present sampling operation com-
pleted.
FE70 to 20D0 hex
FF38 to 1068 hex
DDA0 to 2260 hex
Function
Appendix D