Z0221524ASGR50A5 Zilog, Z0221524ASGR50A5 Datasheet - Page 32

IC MODEM CONTROLLER 44-LQFP

Z0221524ASGR50A5

Manufacturer Part Number
Z0221524ASGR50A5
Description
IC MODEM CONTROLLER 44-LQFP
Manufacturer
Zilog

Specifications of Z0221524ASGR50A5

Data Format
V.21, V.22, V.23, Bell 103, Bell 212A
Baud Rates
2.4k
Interface
Serial
Voltage - Supply
4.5 V ~ 5.5 V
Mounting Type
Surface Mount
Package / Case
44-LQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
Z0221524ASGR50A5
Manufacturer:
Zilog
Quantity:
10 000
PS001907-0904
Command
M
\N
Speaker ON/
OFF Options
Asynchronou
s Terminal
Data
Options
Table 3. AT Command Set (Continued)
Single Chip Modem with Integrated Controller, Data Pump, and AFE
Function and Description
M0
M1
M2
M3
The \N command determines the path of asynchronous format data through the
modem to the terminal. The data path is set at the start of a telephone line
connection. The Communications Mode Options (&Q) determines whether
terminal data is in asynchronous or synchronous format.
\N0
\N1
The speaker is always OFF.
The speaker is ON until the carrier is detected. This value is
the default value in North America.
The speaker is always ON (in this case, the speaker stays
ON after the carrier is detected).
The speaker is off as digits are dialled, but on during
ringback and the until carrier signal is detected.
This command is NORMAL (or buffered) operation. This
mode enables data rate matching between the telephone
line and terminal, and flow control between the modem and
the terminal. In all data modes (V.22bis, V.22, Bell 212A,
V.23, Bell 202, Bell 202T, V.21 and Bell 103), data is
buffered through the modem controller before being
modulated to and from the telephone line.
This command is the DIRECT operation. This mode does
not enable data rate matching, or flow control between the
modem and the terminal. After the CONNECT message is
displayed, the terminal adjusts the data rate to match the
telephone line rate.
In V.23, V.21, Bell 202, Bell 202T, and Bell 103 data
modes, data from the terminal is directly modulated to and
from the telephone line. In V.22bis, V.22 and Bell 212A data
modes, data from the terminal is converted to
SYNCHRONOUS format using ITU V.14 to adjust for small
(up to 2.5%) timing discrepancies in the data rate without
the use of flow control. This value is the default value.
AT Command Set
Z02215
26

Related parts for Z0221524ASGR50A5