SX8724E082TRT Semtech, SX8724E082TRT Datasheet - Page 28

IC DAS PRESSURE/TEMP SENS 16MLPQ

SX8724E082TRT

Manufacturer Part Number
SX8724E082TRT
Description
IC DAS PRESSURE/TEMP SENS 16MLPQ
Manufacturer
Semtech
Series
ZoomingADC™r
Type
Pressure/Temperature Sensorr
Datasheet

Specifications of SX8724E082TRT

Input Type
Differential
Output Type
Digital
Interface
2-Wire
Mounting Type
Surface Mount
Package / Case
16-MLPQ
For Use With
XE8000EV121 - BOARD EVAL FOR SX8723/24
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Current - Supply
-
Other names
SX8724E082TR
ADVANCED COMMUNICATIONS & SENSING
Registers Map
Registers Descriptions
The register descriptions are presented here in ascending order of Register Address. Some registers carry
several individual data fields of various sizes; from single-bit values (e.g. flags), upwards. Some data fields are
spread across multiple registers. Unused bits are ‘don't care’ and writing either 0 or 1 will not affect any function
of the device. After power on reset the registers will have the values indicated in the tables “Reset” column.
RC Register
V1.23 © 2009 Semtech Corp.
RC Register
GPIO Registers
ADC Registers
Mode Register
7:1
0
Bit
Address
0x30
0x40
0x41
0x50
0x51
0x52
0x53
0x54
0x55
0x56
0x57
0x70
-
RC_EN
Name
RegRCen
RegOut
RegIn
RegACOutLsb
RegACOutMsb
RegACCfg0
RegACCfg1
RegACCfg2
RegACCfg3
RegACCfg4
RegACCfg5
RegMode
Register
r
rw
Mode
000000
1
Bits
ZoomingADC™ for Pressure and Temperature Sensing
Reset
1
8
4
8
8
7
8
8
8
7
8
6
Table 18 - RegRCen (0x30)
RC oscillator control
D0 to D3 pads data output and direction control
D0 to D3 pads input data
LSB of the ADC result
MSB of the ADC result
ADC conversion control
ADC conversion control
ADC conversion control
ADC conversion control
ADC conversion control
ADC conversion control
Chip operating mode register
unused
Enables RC oscillator. Set 0 for low power mode.
28
Description
Description
www.semtech.com
SX8724

Related parts for SX8724E082TRT