PC28F128J3D75B Numonyx - A DIVISION OF MICRON SEMICONDUCTOR PRODUCTS, INC., PC28F128J3D75B Datasheet - Page 57

IC FLASH 128MBIT 75NS 64EZBGA

PC28F128J3D75B

Manufacturer Part Number
PC28F128J3D75B
Description
IC FLASH 128MBIT 75NS 64EZBGA
Manufacturer
Numonyx - A DIVISION OF MICRON SEMICONDUCTOR PRODUCTS, INC.
Series
-r
Datasheet

Specifications of PC28F128J3D75B

Format - Memory
FLASH
Memory Type
FLASH
Memory Size
128M (16Mx8, 8Mx16)
Speed
75ns
Interface
Parallel
Voltage - Supply
2.7 V ~ 3.6 V
Operating Temperature
-40°C ~ 85°C
Package / Case
64-TBGA
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
872768
872768TR
872768TR
PC28F128J3D75 872768
PC28F128J3D75B
PC28F128J3D75BTR

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PC28F128J3D75B
Manufacturer:
Micron Technology Inc
Quantity:
10 000
Numonyx™ Embedded Flash Memory (J3 v D, Monolithic)
Figure 27: Protection Register Programming Flowchart
December 2007
316577-06
FULL STATUS CHECK PROCEDURE
Write Protect. Register
Read Status Register
Read Status Register
Program Successful
Program Complete
Data (See Above)
Check if Desired
(Protection Reg.
Program Setup)
Address/Data
SR.3, SR.4 =
SR.1, SR.4 =
SR.1, SR.4 =
Write C0H
Full Status
SR.7 = 1?
Start
Yes
1, 1
0,1
1,1
No
Attempted Program to
Protection Register
Programming Error
Locked Register -
V
PEN
Aborted
Range Error
Protection Program operations can only be addressed within the protection
register address space. Addresses outside the defined space will return an
error.
Repeat for subsequent programming operations.
SR Full Status Check can be done after each program or after a sequence of
program operations.
Write FFH after the last program operation to reset device to read array mode.
SR.3 MUST be cleared, if set during a program attempt, before further
attempts are allowed by the Write State Machine.
SR.1, SR.3 and SR.4 are only cleared by the Clear Staus Register Command,
in cases of multiple protection register program operations before full status is
checked.
If an error is detected, clear the status register before attempting retry or other
error recovery.
Bus Operation
Bus Operation
Standby
Standby
Standby
Standby
Write
Write
Read
Protection Program
Protection Program
Command
Command
Setup
Data = C0H
Data = Data to Program
Addr = Location to Program
Status Register Data Toggle
CE# or OE# to Update Status
Register Data
Check SR.7
1 = WSM Ready
0 = WSM Busy
SR.1 SR.3 SR.4
0
0
1
1
0
0
Comments
Comments
1
1
1
V
Prot. Reg.
Prog. Error
Register
Locked:
Aborted
PEN
Low
Datasheet
57

Related parts for PC28F128J3D75B