Specifications of WD30-SE

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
WD30SE
DeviceNet Wireless Master Station Specifications
DeviceNet setting switch
(SW1)
Wireless setting switch
(SW3)
WCH switch
Set the communication speed and status of the DeviceNet interface here.
Set the switches before turning on the power supply. Only the setting values
detected immediately after the power supply has been turned on are enabled.
Changes to switch settings after the power supply has been turned on are
ignored.
Perform the various settings for TEST and SET modes. Set the switches
before turning on the power supply. Only the setting values detected immedi-
ately after the power supply has been turned on are enabled.
Changes to switch settings after the power supply has been turned on are
ignored.
Set the frequencies for the wireless interface group addresses. The settings
should be made in decimals in a range from 01 to 34 will result in a switch set-
ting error. For normal operation modes, settings outside of the valid range will
SW1
ON
1 2
No.
1
2
3
4
125k
250k
500k
-
No.
3
4
ON
1 2
No.
1
2
3
4
5
6
7
8
Communication
• DeviceNet communication speed settings
SW3
3 4
3 4
speed (bps)
5
6
Contents
Communication
speed selection
Status/No status
Maximum number of I/O points
Contents
(Usually OFF)
(Usually OFF)
Wireless channel monitor
Installation test
Confirmation test
Wireless slave station entry
Wireless slave station deletion
Default configuration
7 8
Contents
Status/No status
Maximum number of
I/O points
OFF
ON
OFF
ON
(MODE1)
(MODE2)
MODE1
1
DIP switch status
ON
Status
1,600/1,600 points
(100 words/100 words)
OFF
OFF
ON
ON
ON
-
-
Performed
Performed
Performed
Entries
Deletes
Default settings
used
MODE2
2
Length of main line: 500m
Length of main line: 250m
Length of main line: 100m
Settings prohibited, no
communication
OFF
-
-
Not performed
Not performed
Not performed
Does not entry
Does not delete
Default settings not
used
OFF
No status
512/512 points
(32 words/32 words)
Remarks
Section 4-1
57