LV8731V-TLM-H ON Semiconductor, LV8731V-TLM-H Datasheet - Page 10

Motor / Motion / Ignition Controllers & Drivers 9-32VSteppingMotor 2chBrush Motor Dr

LV8731V-TLM-H

Manufacturer Part Number
LV8731V-TLM-H
Description
Motor / Motion / Ignition Controllers & Drivers 9-32VSteppingMotor 2chBrush Motor Dr
Manufacturer
ON Semiconductor
Type
Stepper Motor Driverr
Datasheet

Specifications of LV8731V-TLM-H

Product
Stepper Motor Controllers / Drivers
Operating Supply Voltage
9 V to 32 V
Supply Current
3.2 mA
Mounting Style
SMD/SMT
Package / Case
SSOP-44
Operating Temperature
- 20 C to + 85 C
Supply Voltage (min)
9 V
Motor Type
Stepper
No. Of Outputs
2
Output Current
2A
Supply Voltage Range
9V To 32V
Driver Case Style
SSOP
No. Of Pins
44
Operating Temperature Range
-20°C To +85°C
Svhc
No SVHC (20-Jun-2011)
Rohs Compliant
Yes
Lead Free Status / Rohs Status
 Details

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LV8731V-TLM-H
Manufacturer:
ON Semiconductor
Quantity:
8
Part Number:
LV8731V-TLM-H
Manufacturer:
ON
Quantity:
10 000
Part Number:
LV8731V-TLM-H
Manufacturer:
ON/安森美
Quantity:
20 000
Part Number:
LV8731V-TLM-H
0
Description of operation
Input Pin Function
(1) Chip enable function
(2) Drive mode switching pin function
STM mode (DM = Low or Open)
(1) STEP pin function
(2) Excitation mode setting function
(3) Position detection monitoring function
This IC is switched between standby and operating mode by setting the ST pin. In standby mode, the IC is set to
power-save mode and all logic is reset. In addition, the internal regulator circuit and charge pump circuit do not
operate in standby mode.
The IC drive mode is switched by setting the DM pin. In STM mode, stepping motor channel 1 can be controlled by
the CLK-IN input. In DCM mode, DC motor channel 2 or stepping motor channel 1 can be controlled by parallel
input. Stepping motor control using parallel input is 2-phase or 1-2 phase full torque.
This is the initial position of each excitation mode in the initial state after power-on and when the counter is reset.
The MONI position detection monitoring pin is of an open drian type.
When the excitation position is in the initial position, the MONI output is placed in the ON state.
(Refer to "Examples of current waveforms in each of the excitation modes.")
High
High
MD1
Low
High
High
Low
Low
Low or Open
ST
Low or Open
High
High
ST
DM
Input
STP
MD2
High
High
Low
Low
*
Operating mode
Standby mode
Drive mode
DCM mode
STM mode
Mode
2 phase excitation
1-2 phase excitation
W1-2 phase excitation
4W1-2 phase excitation
Excitation mode
Excitation step proceeds
Excitation step is kept
Operating mode
Standby mode
LV8731V
Internal regulator
Operating
Standby
DC motor channel 2 or stepping motor channel 1 (parallel)
Stepping motor channel 1 (CLK-IN)
Channel 1
100%
100%
100%
100%
Charge pump
Operating
Application
Initial position
Standby
Channel 2
-100%
0%
0%
0%
No.A1482-10/26