T3DDT0 GIC, T3DDT0 Datasheet - Page 57

TIME SWITCH, ASTRO, 3-PHASE CONTROL

T3DDT0

Manufacturer Part Number
T3DDT0
Description
TIME SWITCH, ASTRO, 3-PHASE CONTROL
Manufacturer
GIC
Datasheet

Specifications of T3DDT0

Contact Style
SPST
Contact Current Max
8A
Controller Output
Digital
Rohs Compliant
Yes
Supply Monitoring Series CMR - Current Control
• Protection against Overload, Phase Loss,
• Wide range of sensing current : 1A-45A
• Models for 1 Phase and 3 Phase systems
• Auto/Manual Reset selection
• Fail-safe protection
56
EMI/EMC
Conducted Emission
Electrical Fast Transients
Surge
Test Voltage between Input &
Output
Note: In case of Phase loss protection all LED's remains off.
Cat. No.
Parameters
Supply Voltage
Power Consumption
Current Ranges
Trip Type
Thermal Memory
Tripping Class
Start Time
Delay Time
Underload Protection
Phase Imbalance Protection
Phase Loss Protection
Locked Rotor Protection
Phase Reverse Protection
Reset Mode
Test Function
LED Indication
Output Relay Contact
Tolerance
Certification
Mechanical Life Expectancy
Electrical Life Expectancy
Operating Temperature
Storage Temperature
Mounting / Dimensions
Weight
ORDERING INFORMATION
Cat. No.
3 Phase
17A122CB0
17A222CB0
17A322CB0
17B122AA0
17B222AA0
17B322AA0
MOUNTING DIMENSION (mm)
Phase Reverse, and Phase Unbalance faults
6.80
1 Phase
17C112EB0
17C212EB0
17C312EB0
17D112DA0
17D212DA0
17D312DA0
Contact Rating
101.00
89.20
ON
OL
UL
REV/UNB
17A122CB0
220-415 VAC, -20% to +15% 50 / 60 Hz
Inverse Time
40% - 90% (Trip Time: < 5 s)
50% unbalance (Trip Time: < 5 s)
70% of unbalance (Trip Time: < 3 s)
300% of the set value
(Trip Time: < 3 s after starting)
Yes / (0.2 s approx.)
CISPR 14-1 Ed. 5.0 (2005-11) CLASS B
IEC 61000-4-4, Ed. 2.0 (2004-07) Level IV
IEC 61000-4-5, Ed. 2.0 (2005-11) Level III
IEC 60947-5-1 Ed. 3.0 (2003-11) 2 kV
10A, 10, 20, 30
Description
Inverse Time Current Monitoring, 3 - 9 A, 1 NO
Inverse Time Current Monitoring, 8 - 24 A, 1 NO
Inverse Time Current Monitoring,
Definite Time Current Monitoring, 3 - 9 A, 1 NO
Definite Time Current Monitoring, 8 - 24 A, 1 NO
Definite Time Current Monitoring,
Yes
20.50
• Inverse time model with underload,
• Definite time model with underload and
10 VA (Approx)
locked rotor protection and selectable trip class
selectable start and trip time
78.00
38.00
17B122AA0
Definite Time
50% / (Trip Time: < 5 s)
ON: Phase Reverse / BLINK: Phase Unbalance
-
-
15 - 45 A,
15 - 45 A,
1 NO (Fail Safe Protection)
± 5 % of full scale
1 x 10 Operations
1 x 10 Operations
- 10° C to + 60° C
- 25° C to + 70° C
210 g (unpacked)
Base Mounting
5A @ 240VAC
Auto / Manual
1 NO
1 NO
Power ON
Underload
Overload
6
5
3 - 9 A
CONNECTION DIAGRAM
Yes
17C112EB0
110-240 VAC, -20% to +10% 50 / 60 Hz
Inverse Time
10A, 10, 20, 30
40% - 90% (Trip Time: < 5 s)
300% of the set value
(Trip Time: < 3 s after starting)
L1
Motor
L2
CMR
Yes
L3
White
Start
MA
Stop
5 VA (Approx)
0.2 - 30 s
0.2 - 10 s
Control
Power
-
-
-
17D112DA0
50% / (Trip Time: < 5 s)
Definite Time
L1
Motor
L2
CMR
-
-
L3
White
Start / Stop
Control
Power

Related parts for T3DDT0