166981-003 FCI, 166981-003 Datasheet - Page 2

no-image

166981-003

Manufacturer Part Number
166981-003
Description
Manufacturer
FCI
Datasheet

Specifications of 166981-003

Lead Free Status / Rohs Status
Not Compliant
10.0
11.0
12.0
13.0
14.0
15.0
16.0
TITLE
Specification of Requirements for Cable Preparation, Wire Termination and
Copyright FCI
Form E-3334
Rev E
10.1
10.2
10.3
11.1
11.2
12.1
12.2
12.3
12.4
12.5
12.6
12.7
12.8
13.1
13.2
10.2.1
10.3.1
10.3.2
11.1.1
11.1.2
11.1.3
11.1.4
12.6.1
12.6.2
12.6.2.1
12.6.2.2
CONNECTOR SUB-ASSEMBLIES - GENERAL ................................................................................13
ASSEMBLY OF COMPONENTS AFTER WIRE INSERTION ............................................................17
REPAIR PROCEDURES......................................................................................................................21
12.6.2.2.1
12.6.2.2.2
USE OF CONNECTORS WITH MATING PRODUCTS.......................................................................26
NOTES .................................................................................................................................................28
NOTES .................................................................................................................................................28
REFERENCE DOCUMENTS ...............................................................................................................28
Contact Retention ............................................................................................................................13
Connector Insulator Damage ...........................................................................................................14
Wire Terminators .............................................................................................................................14
72476 and 72477 type Metral™ Unshielded Connectors................................................................17
88940 type Metral™ Unshielded Connectors ..................................................................................20
Repair Tooling..................................................................................................................................21
Wire Replacement ...........................................................................................................................21
Damaged Contacts in a Completed Connector ...............................................................................21
Removing Contacts from the Insulator ............................................................................................21
Inserting Contacts into the Insulator ................................................................................................21
Wires Inserted in Wrong Position or Defective Insertion .................................................................22
Replacing Latches ...........................................................................................................................26
Replacing or Removing Covers .......................................................................................................26
72476 and 72477 type Metral™ Unshielded Connectors................................................................26
88940 type Metral™ Unshielded Connectors ..................................................................................26
Assembly of Connectors Using 72392-type Contacts
Termination Tool Misalignment ....................................................................................................14
Automatic Terminators .................................................................................................................14
Hand Tools ...................................................................................................................................16
Assembly of Covers to Connector Sub-Assemblies ....................................................................17
Assembly of Latch Finger to Covers ............................................................................................19
Assembly of Cable Tie .................................................................................................................19
Assembly of Optional Coding Keys to Covers .............................................................................20
Preferred Method of Repair..........................................................................................................22
Alternate Methods of Repair.........................................................................................................23
Wires Inserted in Wrong Position..........................................................................................23
Defective Insertions...............................................................................................................23
Reinsertion of Wire in IDC of Contact ..............................................................................23
Soldering of Wire in Contact ............................................................................................25
TYPE
APPLICATION SPECIFICATION
PDM: Rev:J
NUMBER
PAGE
AUTHORIZED BY
STATUS
STATUS:
J.R. Volstorf
2 of 29
UNRESTRICTED
Released
GS-20-002
REVISION
DATE
25-Apr-06
Printed: Nov 27, 2010
J
GS-01-001
.