DS1005-75 Maxim Integrated Products, DS1005-75 Datasheet - Page 4

no-image

DS1005-75

Manufacturer Part Number
DS1005-75
Description
Active Tapped Delay Line 5 TAP 1-IN 15ns ABS 75ns MAX 14-Pin PDIP N
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of DS1005-75

Package
14PDIP N
Number Of Taps
5
Delay To First Tap
15 ns
Increment Range
5 to 20 ns
Maximum Delay Time
75 ns
Operating Supply Voltage
5 V

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DS1005-75
Manufacturer:
DALLAS
Quantity:
20 000
NOTES:
1. All voltages are referenced to ground.
2. Measured with outputs open.
3. V
4. See Test Conditions.
5. The combination of temperature variations from 25 C to 0 C or 25 C to 70 C and voltage variations
6. All tap delays tend to vary unidirectionally with temperature or voltage. For example, if TAP 1 slows
7. Pulse width and duty cycle specifications may be exceeded; however, accuracy will be application-
TERMINOLOGY
Period: The time elapsed between the leading edge of the first pulse and the leading edge of the
following pulse.
t
1.5V point on the trailing edge, or the 1.5V point on the trailing edge and the 1.5V point on the leading
edge.
t
input pulse.
t
input pulse.
t
pulse and the 1.5V point on the leading edge of any tap output pulse.
t
pulse and the 1.5V point on the trailing edge of any tap output pulse.
WI
RISE
FALL
PLH
PHL
is greater.
from 5.0V to 4.75V or 5.0V to 5.25V may produce an additional input-to-tap delay shift of 1.5 ns or
down, all other taps will also slow down; TAP 3 can never be faster than TAP 2.
sensitive (decoupling, layout, etc.).
(Pulse Width): The elapsed time on the pulse between the 1.5V point on the leading edge and the
4%, whichever is greater.
(Time Delay, Falling): The elapsed time between the 1.5V point on the trailing edge of the input
(Time Delay, Rising): The elapsed time between the 1.5V point on the leading edge of the input
(Input Rise Time): The elapsed time between the 20% and the 80% point on the leading edge of the
CC
(Input Fall Time): The elapsed time between the 80% and the 20% point on the trailing edge of the
= 5V @ 25 C. Delays accurate on both rising and falling edges within 2 ns or 3%, whichever
4 of 6
DS1005