Specifications of ADUM2400CRIZ

No. Of Channels
4
Propagation Delay
32ns
Supply Current
70mA
Supply Voltage Range
2.7V To 5.5V
Digital Ic Case Style
SOIC
No. Of Pins
16
Operating Temperature Range
-40°C To +105°C
ADuM2400/ADuM2401/ADuM2402
PACKAGE CHARACTERISTICS
Table 4.
Parameter
Resistance (Input to Output)
Capacitance (Input to Output)
Input Capacitance
IC Junction-to-Case Thermal Resistance, Side 1
IC Junction-to-Case Thermal Resistance, Side 2
1
2
REGULATORY INFORMATION
The ADuM240x are approved by the organizations listed in Table 5. Refer to Table 10 and the Insulation Lifetime section for details
regarding recommended maximum working voltages for specific cross-isolation waveforms and insulation levels.
Table 5.
UL
Recognized under 1577 component
recognition program
Double/reinforced insulation,
5000 V rms isolation voltage
File E214100
1
2
INSULATION AND SAFETY-RELATED SPECIFICATIONS
Table 6.
Parameter
Rated Dielectric Insulation Voltage
Minimum External Air Gap (Clearance)
Minimum External Tracking (Creepage)
Minimum Internal Gap (Internal Clearance)
Tracking Resistance (Comparative Tracking Index)
Isolation Group
Device considered a two-terminal device: Pin 1, Pin 2, Pin 3, Pin 4, Pin 5, Pin 6, Pin 7, and Pin 8 shorted together and Pin 9, Pin 10, Pin 11, Pin 12, Pin 13, Pin 14, Pin 15,
and Pin 16 shorted together.
Input capacitance is from any input data pin to ground.
In accordance with UL 1577, each ADuM240x is proof tested by applying an insulation test voltage ≥ 6000 V rms for 1 second (current leakage detection limit = 10 μA).
In accordance with DIN V VDE V 0884-10, each ADuM240x is proof tested by applying an insulation test voltage ≥1590 V peak for 1 second (partial discharge detection
limit = 5 pC). The * marking branded on the component designates DIN V VDE V 0884-10 approval.
2
1
1
1
CSA
Approved under CSA Component
Acceptance Notice #5A
Reinforced insulation per CSA 60950-1-03
and IEC 60950-1, 600 V rms (848 V peak)
maximum working voltage
Reinforced insulation per IEC 60601-1
250 V rms (353 V peak) maximum working
voltage
File 205078
Symbol Value
L(I01)
L(I02)
CTI
Symbol
R
C
C
θ
θ
I-O
I-O
I
JCI
JCO
Rev. C | Page 10 of 24
5000
>8.0
>8.0
0.017 min mm
IIIa
>175
Min
Unit
V rms 1-minute duration
mm
mm
V
Typ
10
2.2
4.0
33
28
12
Conditions
Measured from input terminals to output terminals,
shortest line of sight distance through air
Measured from input terminals to output terminals,
shortest distance path along body
Material Group (DIN VDE 0110, 1/89, Table 1)
Insulation distance through insulation
DIN IEC 112/VDE 0303 Part 1
VDE
Certified according to DIN V VDE V 0884-10
(VDE V 0884-10):2006-12
Reinforced insulation, 846 V peak
File 2471900-4880-0001
Max
Unit
Ω
pF
pF
°C/W
°C/W
Test Conditions
f = 1 MHz
Thermocouple located at center
of package underside